650328
14
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
 


13. Troubleshooting
WARNING Risk of electrocution
To test the appliance, it must be supplied with power.
13.1 Display options LED diagnostic "traffic lights"

red illuminates in case of faults
yellow illuminates when the appliance is heating water
green flashing: The appliance is supplied with power
13.2 Fault table


 
The appliance does not start. The shower head / perlators are scaled up. Descale or if necessary replace the shower head /
perlators.
Inadequate flow rate. The sieve in the appliance is dirty. Clean the sieve.
Set temperature is not achieved. One phase down. Check the MCB/fuse in your fuse box.
Heating does not switch on. The air sensor detects the presence of air in the water
and briefly switches the heater off.
The appliance restarts after one minute.
No hot water and no "traffic light" display. The MCB/fuse has responded/blown. Check the MCB/fuse in your fuse box.
Safety pressure limiter AP 3 has tripped. Remove the cause of the fault (e.g. faulty pressure
washer).
Protect the system against overheating by opening
a draw-off valve downstream of the appliance for
1 minute. This depressurises and cools down the
heating system.
Activate the safety pressure switch at flow pressure
by pressing the reset button.
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: Green flashing
No hot water at flow rate of
>3l/min.
Flow sensor (DFE) is not plugged in.
Plug the flow sensor plug back in.
Flow sensor DFE is faulty. Check the flow sensor and replace if necessary.
The set temperature is not achieved.
The set value transducer or connecting cable is faulty or
the connecting cable is not attached.
Attach the connecting cable; replace the set value
transducer if required.
Temperature limiting is activated. Disable temperature limiting.
Traffic light display: Yellow constantly ON;
green flashing
No hot water at flow rate of >3l/min.
The high limit safety cut-out has responded or its lead
is broken.
Check the high limit safety cut-out and replace if
necessary.
The heating system is faulty. Measure the resistance of the heating system and
replace if necessary.
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: yellow constantly ON;
green flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor
if necessary.
Set temperature is not achieved. Appliance operates at its output limit. Reduce the flow rate or install the flow limiter.
Traffic light display: red constantly ON; green
flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor
if necessary.
No hot water The cold water sensor is faulty. Check the PCB and replace if necessary.
Required temperature > 45 °C is not achieved. The cold water inlet temperature exceeds 45 °C. Reduce the cold water inlet temperature to the
appliance.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stiebel Eltron DHB-E 18 SLi 25A electronic wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Stiebel Eltron DHB-E 18 SLi 25A electronic

Stiebel Eltron DHB-E 18 SLi 25A electronic Bedienungsanleitung und Installationsanweisung - Deutsch, Englisch, Holländisch, Französisch, Polnisch - 116 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info