650331
6
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
 


8. Appliance description
The bare wire heating system is suitable for hard and soft water
areas. The heater has low susceptibility to scale build-up.
The appliance is suitable for heating cold water or for reheating
preheated water. For temperatures, see chapter "Specification /
Data table".
The max. inlet temperature for reheating must not be exceeded.
There will be no reheating, if the inlet temperatures exceed this
maximum value.
Observe the "Max. inlet temperature". The appliance can be
damaged at higher temperatures. If a "central thermostat" is
installed (see chapter "Installation / Accessories"), you can limit
the "Max. inlet temperature".
The outlet temperature can be infinitely adjusted. The electronic
control unit enables automatic matching of the electrical output
corresponding to the selected temperature subject to the actual
throughput.
8.1 Standard delivery
- Mounting bracket
- Installation template
- Twin nipple
- Cross-piece
- Tee
- Flat packing
- Sieve
- Flow limiter
- Plastic profile washer
- Plastic cap
- Flexible plastic couplings
- Cap and back panel guides
8.2 Installation
The following conditions have been prepared for the appliance
at the factory:
- Power supply from "below", installation on unfinished walls
- Water connection, installation on unfinished walls
The appliance must be fitted vertically, over or undersink, to a
solid wall.
8.3 Temperature limiting/anti-scalding protection
The maximum temperature can be limited to 43°C via the user
interface on the appliance cap. The following steps are necessary
for this procedure:
Remove the appliance cap.
Remove the electronic PCB from the user interface on the
appliance cap. Be careful of the snap-on hooks.
Move the plug from left to right (position "43 °C").
Refit the user interface, ensuring the snap-on hooks click into
place. Observe the positions of the pushbutton and shaft.
CAUTION Burns
If operating with preheated water, the set temperature
limit and anti-scalding protection may be ineffective.
In this case, restrict the temperature at the
upstream central thermostatic valve; see chapter
Accessories”.
2602�02�0833
8.4 Installation versions
The following installation versions are possible/permissible:
- Power supply for unfinished walls - from above
- Power supply for finished walls
- Water installation for finished walls
- Installation with repositioned appliance cap
- Installation for offset tiles
- Installation of a load shedding relay
8.5 Accessories
Taps
- WKMD – twin-lever pressure-tested kitchen tap
- WBMD – twin-lever pressure-tested bath tap
Plug G½A
These plugs are required if you use twin-lever pressure-tested
taps for finished walls other than the ones recommended by us.
Installation sets for installation on finished walls
- Solder fitting – copper pipe for solder connection Ø12 mm.
- Compression fitting – copper pipe.
- Compression fitting – plastic pipe
(suitable for Viega: Sanfix-Plus or Sanfix-Fosta).
Universal mounting frame
- Mounting frame with electrical wiring.
Pipe set for undersink appliances
The set for undersink installation is required if you want to have
the water connections (G⅜A) above the appliance.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stiebel Eltron DHB-E 24 SLi electronic wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Stiebel Eltron DHB-E 24 SLi electronic

Stiebel Eltron DHB-E 24 SLi electronic Bedienungsanleitung und Installationsanweisung - Deutsch, Englisch, Holländisch, Französisch, Polnisch - 116 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info