469640
8
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
8
S2
R2
ON/OFF switch -
thermostat
Selector button -
room temperature
Selector button
- charging
7843.01
20
21
S2
R2
8723.01
The discharge control unit must be installed
by an approved qualifi ed installer, following
these Operating and Installation Instructions
as well as the instructions for the storage
heater.
All electrical connection and installation
work is to be carried out in accordance with
VDE 0100 provisions, the regulations of the
electricity supply utility companies concerned,
and the corresponding national and regional
regulations.
2.1 Packing unit
1 discharge control unit with
connection lead for charge and discharge
control unit
6-pin plug connector with cable harness
1 ON/OFF switch
1 adjuster (potentiometer) with connection
lead
1 temperature selector button
1 set of operating and installation instructions
1 room temperature sensor with 2 screws
2 separate switch leads for switches
2.2 Installation
Before starting installation work, isolate the
storage heater from the electricity supply.
RTI-E3
The RTI-E3 is an electronic 2-point control
unit; i.e. the blower of the storage heater is
switched on by the RTI-E3, operated at a con-
stant speed, and then switched off again.
RTI-EP2
The RTI-EP2 is an electronic proportional
control unit; i.e. the speed of the storage hea-
ter blower motor is steplessly adjusted by the
RTI-EP2 to suit the heat requirement.
In this situation, the speed regulation of the
blower motor is effected as a function of the
difference between the room temperature
(the actual temperature) and the temperature
which has been set at the selector button R2
(the reference temperature). The smaller this
difference, the lower the speed of the blower
motor.
However, if the storage heater is being ope-
rated with a supplementary heating system,
then the RTI-EP2 automatically switches over
to a 2-point control arrangement; i.e. if heat is
being given off, then the blower motors only
run at full capacity. If the supplementary hea-
ting is switched off by means of the switch on
the operating panel, then the RTI-EP2 again
operates as a proportional control unit.
Briefl y the most important
1.1 Mode of operation
The discharge control unit is switched on and
off by means of the S2 switch on the control
panel of the storage heater (ON = "
").
The room temperature desired can be step-
lessly adjusted between about 5 to 35 °C by
means of the R2 selector button on the ope-
rating panel. If the selector button is in the
central position, the room temperature will be
kept to a constant temperature of about 20 °C.
If the room temperature drops below the
preset value, the discharge control unit auto-
matically switches on the storage heater blo-
wer motors, so that the stored heat is blown
into the room.
After adjusting the temperature it may last y
few minutes before the blower will start due
to technical reasons.
On very cold days, it is recommended that
the discharge control unit be switched on if
no-one is going to be present for several days,
in order to keep the room temperature at
about 10 °C, for example, so as to prevent
the building or the room from becoming too
cold (to protect against freezing).
Night-time heating reduction
By utilising an external switch or timeclock, a
temperature reduction of approx. 4 K can be
achieved.
2. Installation instructions for the professional
1. Operating instructions for the user and the professional
When connecting the storage heater
to an automatic charging control
device, it is possible, even with the fuses
removed, that voltage will still be present at
the terminals A1/Z1 - A2/Z2.
If several storage heaters are being set up
next to one another, care is to be taken to
ensure that the discharge control unit is
installed in the right-hand outer device. This
guarantees that the room temperature can be
detected without any problem.
2.2.1 Installation sequence
Remove the air outlet and inlet grilles, the
front wall, and the right side wall, as descri-
bed in the installation instructions for the
storage heater.
Push the blind cap for the switch (20) and
temperature selector button (21) out of
the operating panel from the switchbox
side, using a mechanical aid.
Push the ON/OFF switch (S2) with the
„flat plug upwards“ into the operating pa-
nel from the front.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stiebel Eltron RTI-EP2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info