813429
26
Zoom out
Zoom in
Vorherige Seite
1/44
Nächste Seite
26
600mm min
1000mm max
unsupported
Elbow with access cover
Size Stovax Part No.
6" 4612
Flue Pipe 915mm (3ft)
Size Stovax Part No.
6" 4602
To chimney connection as
detailed in building regulations
10
2. CO Alarms
All open flued appliances can be affected by temporary
atmospheric conditions which may allow fumes to enter
the house. Building regulations require that whenever
a new or replacement fixed solid fuel or wood/biomass
appliance is installed in a dwelling a carbon monoxide
alarm must be fitted in the same room as the appliance.
Further guidance on the installation of the carbon
monoxide alarm is available in the latest edition of
BS EN50292 and from the alarm manufacturer's
instructions.
HETAS recommend the unit is permanently fixed
in accordance with the manufacturer's installation
instructions or with the guidance contained in Approved
Document J where no other information is available.
Provision of an alarm must not be considered a
substitute for either installing the appliance correctly
or ensuring regular servicing and maintenance of the
appliance and chimney system.
Installation Instructions
CENTRAL HEATING SYSTEM
When designing a heating system in the UK the
following standards must be observed:
BS EN 14336:2004 Heating Systems In Buildings,
Installation & Commissioning of Water Based
Heating Systems.
BS EN 12828 2003 Heating Systems in Buildings,
Design of Water Based Heating Systems.
BS EN 12831: 2003 Heating Systems in Buildings,
Method for Calculation of the Design Heat Load.
1. General
This appliance gives out heat in two ways:
Directly into the room in which it is fitted through
convection and radiation.
Hot water to heat radiators and domestic hot water.
The installation must comply with building regulations and
use best practice advice.
IMPORTANT:
FAILURE TO ADD AND MAINTAIN A SUITABLE
CORROSION INHIBITOR IN THE BOILER WATER
CIRCUIT MAY INVALIDATE YOUR PRODUCT
WARRANTY.
2. Boiler Sizing
2.1 It is very important to determine the correct size of appliance
for the house:
Too big a boiler will run too hot and will not be efficient.
Too small a boiler will not maintain the desired temperature.
2.2 Size the boiler correctly by calculating the following heat loads:
RADIATORS - the amount of heat required to run the
radiators efficiently. The correct size of radiator depends on
the required temperature for the room, the room heat losses
andtheradiatormanufacturer’sguides.
HOT WATER - the amount of heat required to provide the
desired amount of domestic hot water.
LOSSES – the amount of heat lost in pipe work - typically
10% of the combined radiators and hot water loads.
There are national guidelines for calculating these figures*.
2.3 Careful consideration must be given to where the appliance
is fitted. It must be sized correctly for the heat load required
and the size of the room. These requirements can be found
in the Installation Checklist.
2.4 All Stovax appliances are thermostatically controlled. The
burning rate is adjusted to the demands of the connected heat
load. If the radiators do not require heat then the thermostat
will act to shut down the appliance and the direct heat output
to the room where it is fitted will reduce (see heat output graph
on page 15 to show the ratio between direct heat output and
water heat output). To prevent the room becoming too cold, fit
a thermostatically controlled radiator as well as the appliance.
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stovax View High Output Boiler Stoves wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info