FIRST USE / OPERATION
Please note: never transport the device with a full water tank.
Possible hazards:
too much water from water tank comes into the Main Base.
water can easily come out from the Main Base.
the water tank can fall off from the Main Base and get damaged due to the heavy weight from
the water (and water can leak on to the floor).
1. The Stylies SIRIUS humidifier should be placed first with empty Water Tank (13) in a suitable lo-
cation.
2. When the device is in the desired location: remove the cover (4) at the rear side (magnetic
catch).
3. Hold the water tank (13) firmly by the handle, swivel outwards and pull it upward.
4. Fill Water Tank (13) with fresh water (max. 3.5 l) and screw the Tank Cover (15) back on firmly
and check that it is sealed properly. Place Water Tank on base, and you should hear a bubbling
sound (water collector filling).
5. Plug Power Cable into the power socket.
6. Switch on the device: by touching the «ON/OFF» key on the control panel (1). The display will
show «ON» briefly followed by the current humidity, e.g. «41». Shortly after this, the sound of the
water boiling can be heard and hot steam will be emitted (do not touch!).
Caution: If the red «No Water» warning lights up, the humidifier cannot be switched on. Check
if the water tank is full. If so, it may take a moment to refill the water collector (20) if necessary
(the red light «No Water» then goes out).
7. Never point the steam outlet at walls or furniture, etc. On the display (6), it shows the current
humidity level in the room, e.g. «41 %».
8. The desired air humidity level can be selected by repeatedly touching the «HUMIDIT key
(35–75 % rel.). We recommend 40-60 % rel. air humidity. As soon as the display shows the
current relative air humidity again, the humidity setting is saved and automatically monitored.
Set «CO» for continuous operation without humidity monitoring, but this may cause excess hu-
midity if used too often. The humidifier starts automatically as soon as the humidity is lower
than the setting, and stops when it is higher. During humidification the current air humidity is
displayed.
Note: If «C (continuous operation) is set, the humidifier WILL NOT STOP automatically. To
avoid excessive humidity, use «CO» for a short time only. The device will not switch on if the air
humidity level has been set too low.
9. Set the desired humidifying capacity: by repeatedly touching the «OUTPU key (1= low, 3 =
high).
10. Activate the automatic shutdown time: by repeatedly touching the «TIMER» key. Adjust the
shutdown time in hours (01-12 hours, or «00» to quit timer).
11. Night mode: touch the «NIGHT MODE» key to dim the light. Switch off function by touching any
function key.
12. «No water» warning: this red LED lights up if the water collector is empty or too low. In this
case turn the device off by touching the «ON/OFF» key and fill the tank with fresh water. Then
replace the tank in the base and turn the power on again.
Note: When you remove the tank, some water can flow out of it. To prevent damage, always
turn off the power when the «Low water» warning lights up.
CLEANING PROCEDURE
Switch off the device and unplug the power cable from the socket before all maintenance work
and after each use.
Never submerge the device in water (this can result in short-circuiting). To clean the device,
simply wipe it with a damp cloth and then dry it thoroughly. Descale the humidifier as
appropriate for the hardness of the water, but at least once a week: First remove the water
tank and clean it with a brush. Descale the water collector (20) and the vaporizing plate (21) in
the base with a standard descaler and then rinse it thoroughly. Make sure no water penetrates
inside. So only fill with descaler/water mixture to a height of 2-3 cm.
Reassemble the device completely before use.
Thoroughly rinse out the water tank on a regular basis.
USEFUL INFORMATION:
Information how a vaporizer works
How does the vaporizer work? The vaporizing plate in the interior of the device causes the water
to heat up. The steam is emitted through the opening (2) on top of the device and increases
humidity in the room. Using the hygrostat (see next section), the air humidity in the room can be
monitored and regulated. A vaporizer boosts humidity very quickly. The water is sterile because it
has been boiled.
Hygrostat
The standard-tolerance of an integrated hygrostat is +/- 10%. That means the effective relative
humidity level can deviate accordingly. Please ensure that the hygrostat is never covered
otherwise it won’t function properly.
Tips for water
Do not use water that has been subject to salt-based softening in a descaling system. These
systems replace the calcium with salt, which then settles in the room as a white deposit.
Clean water must always be used to ensure that the air remains hygienic to breathe. The device,
and the water tank in particular, must always be hygienically clean.
TECHNICAL DATA
Dimensions 300 x 160 x 390 mm (width x depth x height)
Weight approx. 2.40 kg
Mains voltage 220-240 V / 50 Hz
Power consumption 350 W
Humidifying capacity up to 350 g/h
Automatic shutoff yes
Water tank capacity 3.5 litres /0.92 US gallons
Suitable for room sizes of 45 m² / 110 m³
EU compliance CE/WEEE/RoHS
Technical changes and errors reserved.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stylies Sirius wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info