545026
3
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
32
Getting accurate readings
To ensure accuracy, readings should be taken without clothing and under consistent conditions of hydration. If you do not
undress, always remove your socks or stockings, and be sure the soles of your feet are clean before stepping on the measuring
platform. Be sure that your heels are correctly aligned with the electrodes on the measuring platform. Don’t worry if your feet
appear too large for the unit -accurate readings can still be obtained if your toes overhang the platform.
It is best to take readings at the same time of day. Try to wait about three hours after rising, eating, or hard exercise before taking
measurements.
While readings taken under other conditions may not have the same absolute values, they are accurate for determining the
percentage of change as long as the readings are taken in a consistent manner. To monitor progress, compare weight and body fat
percentage taken under the same conditions over a period of time.
Note : An accurate reading will not be possible
if the soles of your feet are not clean, or if
your knees are bent or you are in a sitting
position.
Heels centered on
electrodes
Toes may overhang
measuring platform
Automatic shut-down function
The automatic shut-down function shuts off the power automatically in the following cases:
If you interrupt the measurement process, the power will shut down automatically within 10 to 20 seconds, depending upon the
type of operation.
If an extreme weight is applied to the platform.
During programming, if you do not touch any of the keys or buttons within 60 seconds.*
After you have completed the measuring process.
Note : If the power shuts off automatically, repeat the steps from “Setting and storing personal data in memory” (p.4).
You can switch the unit indication by using the switch on the back of the scale as
shown in the figure.
The unit should be turned on to switch the weight mode.
Note : If weight mode is set to pounds or stone-pounds, the height programming
mode will be automatically set to feet and inches.
Similarly, if kilograms is selected, height will be automatically set to centimetres.
Switching the weight mode
Note : For use only with models containing the weight mode switch
Positioning the Monitor
Place the measuring platform on a hard, flat surface where there is minimal vibration to ensure
safe and accurate measurement.
Use carpet feet when the scale is used on soft surface, such as rugs or carpetings.
Note : To avoid possible injury, do not step on the edge of the platform.
Handling Tips
This monitor is a precision instrument utilizing state-of-the-art technology.
To keep the unit in the best condition, follow these instructions carefully:
Do not attempt to disassemble the measuring platform.
Store the unit horizontally, and place it so that the buttons will not be pressed accidentally.
Avoid excessive impact or vibration to the unit.
Place the unit in an area free from direct sunlight, heating equipment, high humidity, or extreme temperature change.
Never submerge in water. Use alcohol to clean the electrodes and glass cleaner (applied to a cloth first) to keep them shiny;
avoid soaps.
Do not step on the platform when wet.
Do not drop any objects onto the platform.
Do not use this scale while operation transmitters (such as a cell phone) as this may affect your results.
Preparations before use
Inserting the Batteries
Turn the scale over and remove the battery cover by releasing the latch, install 2 pieces of new
battery (included) with correct polarity as indicated.
Note : Be sure that the polarity of the batteries is set properly. If the batteries are incorrectly
positioned the fluid may leak and damage floors. If you do not intend to use this unit
for a long period of time, it is advisable to remove the batteries before storage.
Please note that the included batteries from factory may have decreased energy levels over time.
Features and functions
7. Personal keys
8. Weight-Only
Key
6. Arrow (Select) Buttons
Accessories
9. Lithium Batteries
CR2032 (2)
1. Display
Screen
2. Ball-of Foot
Electrodes
4. Heel
Electrodes
5. Set Button
Open as shown.
Direction of the batteries.
10. Carpet Feet (4)
3. Features
Buttons
Detachable Carpet Feet
(only for piles up to 0.4”
(10 mm) thick)
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Tanita BC-350 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info