order. Hoses shall be complete with leak-free
disconnect couplings and in good condition. Be-
fore using the recovery machine, check that it is
in satisfactory working order, has been properly
maintained and that any associated electrical
components are sealed to prevent ignition in
the event of a refrigerant release. Consult man-
ufacturer if in doubt.
- The recovered refrigerant shall be returned to
the refrigerant supplier in the correct recovery
cylinder, and the relevant Waste Transfer Note
arranged. Do not mix refrigerants in recovery
units and especially not in cylinders. If compres-
sors or compressor oils are to be removed,
ensure that they have been evacuated to an
acceptable level to make certain that ammable
refrigerant does not remain within the lubricant.
The evacuation process shall be carried out pri-
or to returning the compressor to the suppliers.
Only electric heating to the compressor body
shall be employed to accelerate this process.
When oil is drained from a system, it shall be
carried out safely.
COMPETENCE OF SERVICE
PERSONNEL
GENERAL
- Special training additional to usual refrigerat-
ing equipment repair procedures is required
when equipment with ammable refrigerants is
affected.
- In many countries, this training is carried out by
national training organisations that are accred-
ited to teach the relevant national competency
standards that may be set in legislation.
- The achieved competence should be docu-
mented by a certicate.
TRAINING
- The training should include the substance of
the following:
- Information about the explosion potential of
ammable refrigerants to show that ammables
may be dangerous when handled without care.
- Information about potential ignition sources,
especially those that are not obvious, such
as lighters, light switches, vacuum cleaners,
electric heaters.
- Information about the different safety concepts:
- Unventilated – (see Clause GG.2) Safety of the
appliance does not depend on ventilation of
- the housing. Switching off the appliance or
opening of the housing has no signicant effect
on the safety. Nevertheless, it is possible that
leaking refrigerant may accumulate inside the
enclosure and ammable atmosphere will be
released when the enclosure is opened.
- Ventilated enclosure – (see Clause GG.4) Safe-
ty of the appliance depends on ventilation of
- the housing. Switching off the appliance or
opening of the enclosure has a signicant effect
- on the safety. Care should be taken to ensure a
sufcient ventilation before.
- Ventilated room – (see Clause GG.5) Safety of
the appliance depends on the ventilation of
- the room. Switching off the appliance or open-
ing of the housing has no signicant effect on
- the safety. The ventilation of the room shall not
be switched off during repair procedures.
- Information about the concept of sealed compo-
nents and sealed enclosures according to IEC
60079-15:2010.
- Information about the correct working proce-
dures:
COMMISSIONING
- Ensure that the oor area is sufcient for the
refrigerant charge or that the ventilation duct is
assembled in a correct manner.
- Connect the pipes and carry out a leak test
before charging with refrigerant.
- Check safety equipment before putting into
service.
MAINTENANCE
- Portable equipment shall be repaired outside or
in a workshop specially equipped for servicing
units with ammable refrigerants.
- Ensure sufcient ventilation at the repair place.
- Be aware that malfunction of the equipment
may be caused by refrigerant loss and a refrig-
erant leak is possible.
- Discharge capacitors in a way that won’t cause
any spark. The standard procedure to short
circuit the capacitor terminals usually creates
sparks.
- Reassemble sealed enclosures accurately. If
seals are worn, replace them.
- Check safety equipment before putting into
service.
REPAIR
- Portable equipment shall be repaired outside or
in a workshop specially equipped for servicing
units with ammable refrigerants.
- Ensure sufcient ventilation at the repair place.
- Be aware that malfunction of the equipment
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Taurus Alpatec AC 3100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info