RANGE OF INTERNAL THERMOSTAT
The internal thermostat can be set at a desired temperature between 16 and 32°C. Note that
whether the desired value is achieved depends on the room size, temperature and insulation of
the room.
RANGE OF HEAT PUMP FUNCTION
The heat function can be used when the external ambient temperature is above -15°C. The
performance of the heat pump will degrade with lowering external temperatures. Please note the
performance will reduce when the outdoor temperature drops below 5°C.
CAPACITY
The required cooling or heating capacity depends greatly on the location and/or use of the room
where the air conditioner is installed. Strong sunlight and the presence of people, lights or
equipment create an additional heat load. Normal living spaces require about 100 W per square
metre of floor surface. In strong sunlight or if other sources of heat are present, this may be as
much as 350 W/sqm.
Tip: On warm days, let the air conditioner cool the room as much as possible during the night and
set the temperature constant from night to daytime.
EMERGENCY START
In the event of a problem, the air conditioner can be operated using the emergency button under
the panel in the interior unit. Open the front panel and press the button, the air conditioner will:
-heat if the room temperature is 20 °C or less, cool if the room temperature is 25 °C or more and
for values in between: dehumidify in a model without a heat pump and in a model with a heat
pump in fan mode.