Placement of the sensor
The unit should be placed in the indoor in a location with
good ventilation, not in a cabinet. Mounting on a wall is
possible too. Preference is given to the placement on
the inside of exterior walls, as they are particularly
susceptible to mold growth.
Technical Data
Batteries: 2x AA (LR03, Micro)
alkaline
Battery life: approx. 2 years
Measuring range temperature: -9.9 °C to + 59.9 °C
Accuracy: 0.8 °C
Measuring range humididty: 1%-99% rH
Accuracy: from 0°C - 30°C +/-3%
else +/-4%
Measurement interval: every 6s
Transmission interval: at measurement
difference of > 1°C
or > 3% rH immediately
otherwise every 10
minutes
Transmission range: 100m (open area)
Transmission frequency: 868 MHz
Maximum transmission
power: -4.82dBm
More information and detailed instructions can be found
in the app at “Info” or at www.mobile-alerts.eu
Summary of the Declaration of Conformity: We hereby
declare that this device does comply with the
requirements of RED Directive 2014/53/EU.
The declaration of Conformity can be found at:
www.mobile-alerts.eu/technoline/doc
Old batteries do not belong into general
household waste. You are obliged to return
used batteries to your vendor or collection
points.
Electrical devices have to be disposed
separately from the general household waste.
Take your old electronics to your local waste
collection point or recycling centre.