27
CARE AND MAINTENANCE:
•
Avoid placing the unit in areas prone to vibration and
shock as these may cause damage.
•
Avoid areas where the unit can be exposed to sudden
changes in temperature, i.e. direct sunlight, extreme cold
and wet/moist conditions as these will lead to rapid
changes which reduce the accuracy of readings.
•
When cleaning the LCD and casing, use a soft damp
cloth only. Do not use solvents or scouring agents.
•
Do not submerge the unit into water.
•
Immediately remove all low powered batteries to avoid
leakage and damage. Replace only with new battery of
the recommended size.
•
Do not make any repairs to the unit. Please return it to
the original point of purchase. Opening and tampering
with the unit may invalidate the warranty.
SPECIFICATIONS:
Temperature measuring range
Indoor : -9.9°C to +59.9°C with 0.1°C resolution
(14.1°F to 139.8°F with 0.2°F resolution)
(“OFL” displayed if outside this range)
Temperature checking interval
Indoor : every 60 seconds
Humidity measuring range
Indoor : 20% to 95% with 1% resolution
(“—“ displayed if temperature is OFL; “19%”
displayed if below 20%, “96%” displayed is above
95%)
Power consumption
Alkaline rechargeable battery :
1 x AA, IEC LR6, 1.5V (included), rechargeable by solar cell
Rechargeable Alkaline battery life :
18 – 60 months, depending on usage
Primary Alkaline battery :
1 x AA, IEC LR6, 1.5V battery (not included)
Primary Alkaline battery life : about 24 months