RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 11.15
11.11. SPECIAL FUNCTIONS AND PASSWORD
The table below details the special functions and passwords available on the machine:
Keys Password Function
0-1 6144 Configuration of SW parameters as described in paragraph 9.2.
0-1 2406 Modifying the working parameters as described in paragraph 9.5.
0-3 2406
Partial display of working parameters as described in paragraph
9.3.
0-3 6144
Complete display of working parameters as described in paragraph
9.4.
1-4-7 none Manual lubrication with a duration of 10 seconds.
Mem.prog - Enter 1508 Save program in memory.
Mem.prog-0 1508 Delete program from memory.
Mem.prog-8 1508 Delete all programs in memory.
Runrace Test-0 2406
Automatic incline test: 3% up and 2% down up to the maximum
incline, then 3% down and 2% up, and so on. To abort press the
CLEAR key.
Medical Tests 2512 Maximal tests.