18
Operation instructions of remote control
The air conditioner can be controlled with the remote control. Two AAA-batteries are required to use the remote
control.
POWER : Press the POWER button to turn the unit on and off.
MODE : Press the MODE button to switch between cooling, dry, fan modes.
UP : Press the UP button to increase the desired temperature and set the
duration of the timer.
DOWN : Press the DOWN button to reduce the desired temperature and set the
duration of the timer.
FAN : Press the FAN button to cycle between high, medium and low fan
speeds.
TIMER : Press the TIMER button to set the duration of the power on or power
off timer.
SWING : Press the swing button to change the orientation of the louvres to
direct the air
TEMPERATURE UNIT : Press to switch between displaying the temperature in
Celsius and Fahrenheit.
SLEEP MODE : Press to turn on the sleep mode. The unit will work with energy
saving logic and the lowest fan speed.
IV. Protection function
1: Frost Protection Function:
In cooling mode, if the temperature of the exhaust pipe is too low, the unit will automatically enter protection
status; if the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to normal
operation.
2: Overflow Protection Function:
When water in the water pan exceeds the warning level, the unit will automatically sound an alarm, and the
"FULL" indicator light will flash. At this point, you need to move the drainage pipe connecting the unit or the
water outlet to sewer or other drainage area to empty the water (details see Drainage Instructions at the end of
this chapter). After the water is emptied, the unit will automatically return to the original state.
3: Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection function after the compressor
is turned off.
V. Installation and adjustment