1 - Lens
2 - Probe
3 - Battery compartment
4 - Luminous diodes to show temperature mode : ear or forehead
5 - Screen
6 - Take temperature and memory function button
7 - On/Off and Ear or forehead temperature Mode button
8 - Protection/vertical storage cap.
Precautions for use
This ear and forehead thermometer receives the infra-red rays emitted by the skin’s surface and
in the ear drum area. It allows you to check your child’s temperature easily. This is how to use
the appliance:
• The TEFAL thermometer is exclusively dedicated to take ear or forehead temperatures.
We would like to re-iterate that this appliance does not replace the advice of a doctor. In case of
doubt or fever, contact your doctor. TEFAL cannot be held responsible for poor interpretation of results.
The simple take of temperature cannot be considered as a medical advice, DO NOT
modify the proportion of any drugs prescribed by your doctor without seeking medical advice first.
• To ensure the reading is accurate, the probe and the lens must be absolutely clean.
• Do not use the thermometer if it has been dropped or shows any signs of damage
• Always place the protection cap back after use.
• In cases of movement from one room to another, wait for half an hour minimum before using
the appliance.
• Wait for half an hour after physical training, bathing or eating before measuring temperature.
• Keep the thermometer out of reach of children.
• Do not expose the thermometer:
- To any warm sources (radiator, sun rays, ...)
- To dust or humidity.
• Never immerse the thermometer in liquid.
• Do not touch the lens with your fingers.
BODY TEMPERATURE: the normal human body temperature varies during the day. It is measured
along a scale of values defined according to the part of the body where the temperature is taken:
- Rectal measurement: 36,6° - 37,8°C
- Axillary measurement (under the arm): 34,7° - 37,3°C
- Oral measurement (in the mouth) or forehead: 35,5° - 37,5°C
- Ear measurement: 35,8° - 37,8°C
Warning, this appliance is not suitable for dectecting hypothermia.
Average temperatures
Forehead Ear Rectal Oral Axillary
temperature temperature temperature temperature temperature
36,1°C 36,4°C 37,0°C 36,6°C 36,1°C
24
Technical specifications
Measurement range 20°C / 42,2°C
Screen resolution 0,1°C
Precision from 32°C to 42°C: +/- 0,2°C
< 32°C and > 42°C: +/- 0,3°C
Operation conditions - +16°C / +35°C
room temperature Relative humidity less than 85%
Storage conditions - 20°C / +80°C
Relative humidity less than 95%
Energy source 1 lithium battery 3V type CR2032
Service life : approximately 5000 measures
In compliance with the European directive 93/42 (Medical appliances) and EN 12470-5
(medical thermometer).
CE 0120 marking.
Comments: these technical specifications may be subject to modifications to improve the
appliance, without prior warning.
Made in China by Hubdic CNS
Imported and distributed by TEFAL SAS
Italia - EC Representative : Bremed Italia S.r.l. Via Alviano 4/1 Gorizia - Italia
TEFAL SAS BP 89 74156 RUMILLY Cedex FRANCE
Before first use
Installing the battery
The appliance is delivered with a lithium battery 3V (CR2032) already in place.
At the first use, open the battery cover then remove the strip which ensures the protection of the
battery (fig. 1/fig. 2). Replace the cover (fig. 3).
Functionning
Ear measurement
• Remove the protection cap.
• To switch on press and hold the button until the indications in fig. 4 are displayed in the
screen the appliance automatically displays the Ear mode. The screen shows the corresponding
function fig. 5 and the luminous diode corresponding to the symbol blink 5 times.
• Gently pull the ear upwards and backwards to straighten the ear canal. Insert the thermometer
into the ear canal fig. 6.
25
GB
TE211422 Notice Thermo Auri 7 L 13/10/06 11:56 Page 24
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Tefal BH1110 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info