7
PROBLEMS CAUSES SOLUTIONS
The generator does
not come on and
the thermostat light
is not illuminated.
The appliance is not switched
on.
Check that your appliance is
correctly plugged in
Water runs out of
the holes in the
soleplate.
Water has condensed in the
pipes because you are using
steam for the first time or you
have not used it for some time.
Press on the steam control button
away from your ironing board until
the iron produces steam.
The soleplate is not hot enough.
Wait for the thermostat light togo out
before activating the steam button.
Your thermostat is faulty: the iron
is not hot enough.
Contact an Approved Service Centre.
Water streaks
appear on the
linen.
Your ironing board is saturated with
water because it is not suitable for
use with a steam generator.
Check that your ironing board is
suitable.
Storing the generator
• Warning: do not touch the soleplate while still hot.
•
Fold the carrying arm down onto the iron until it clicks into position, ensuring that your iron is
safely locked onto its housing (depending on model).
• Store the electrical cord in its storage place - fig.8.
•
Storing the steam cord - fig.9.
• Leave the iron (and the iron rest) to cool down for 1 hour before storing it away.
Maintenance and cleaning
Before cleaning, ensure that your steam generator is unplugged and that the soleplate and the iron rest have coo-
led down.
Do not use detergent or descaling products for cleaning the soleplate or the base unit.
Never hold the iron or the base unit under the tap.
Cleaning the soleplate
• Regularly clean the soleplate with a non-metallic sponge.
Cleaning the unit
• Clean the plastic parts of the appliance occasionally with a soft dampened cloth.
Rinsing the boiler (once a month)
• Be careful : To extend the life of your boiler and to avoid the building up of scale, it
is essential that you rinse out the boiler at least after every 10 uses (approximately
once a month).
• Check that the generator is cold and unplugged for more than 2 hours.
• Using a jug, fill the boiler 3/4 full with untreated tap water- fig.10
• Shake the base unit for a few moments and then empty it completely over your
sink - fig.11.
• To obtain the best results, we advise you to repeat this operation.
A problem with your generator ?
If your water is hard,
increase the frequency.
In particular, do not use
descaling agents for
rinsing out the boiler, as
they could damage it.