CONVERSIONS
FIG. 14
BURNER ARRANGEMENT ON THE HOT PLATE
U - LPG 2.75 0,94 11.9 85
NATURAL 1.00 1,76 15.0 Fully
Closed *
U - LPG 2.75 0,91 10.8 41
NATURAL 1.00 1,55 12.0 1/2 *
U - LPG 2.75 0,70 6.3 32
NATURAL 1.00 1,20 7.0 3/8 *
BURNERS
N°
DESCRIPTION GAS NORMAL
PRESSURE INJECTOR
DIAMETER NOMINAL HEAT
INPUT (MJ/h)
(kPa) (1/100 mm) MAX. 1/100 mm
EH/60 4G AI AL TR CI model
U - LPG 2.75 0,53 3.6 30
NATURAL 1.00 0,90 4.0 1/8 *
1 ULTRA RAPID
2 RAPID
3 SEMIRAPID
4 AUXILIARY
BY
PASS
* By -pass screw adjustment is the number of turns from fully closed position.
13