688852
18
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
Energy 4010 G Vers. 001
18
G
B
6.5 Control and alarm functions (Fig. 30)
2 Display: when the generating set has started
up, the total running hours will be displayed.
Press the key provided below the control panel
display unit (Fig.30 Ref.9) to display the number
of generating set operation hours since the latest
engine oil change.
3 High temperature indicator: this warning light
will light up when the temperature of the
generating set goes over its safety value; the
engine will stop at the same time.
4 Engine oil minimum level indicator: this
warning light will light up to indicate that oil in the
engine has gone below the minimum level. A
safety system will kill the engine automatically to
prevent failures.
5 Engine startup failed: this warning light will
light up to indicate that the generating set has not
started up, after all four start-up attempts.
7 Change oil: this warning light will light up when
the engine has reached 100 running hours since
the latest oil change. Every time the oil is
changed, the After-sales service staff must reset
the timer to zero.
8 Fuel warning: this warning light will light up
when the fuel level inside the extra tank has gone
below its reserve level (about 4 litres)
9 Display time changeover switch: press this
switch to display the running hours since the
latest engine oil change.
10 Reset: When the display shows characters
without any apparent logic, the panel needs to be
reinitialised. Press the Reset key (Fig.30 Ref. 10)
and, holding it down, switch on the panel. When
4 zeroes (0000) are displayed, the panel has
been reinitialised.
6.6 Control panel alarm causes and resetting
During generating set use, alarm signals may be
displayed referring to engine oil checks. After
checking the engine oil, the control panel must
be reset in the following way:
Alarm: the red ‘service’ light is flashing.
Cause: 50 hours have elapsed since the latest
engine oil change and oil level should be
checked.
How to reset the alarm: press the partial
counter key (Fig.30 Ref.9) and while holding it
down, turn the panel on and release the push-
button when the unit has started up
Alarm: the red ‘service’ light is lit.
Cause: 100 hours have elapsed since the latest
engine oil change and engine oil should be
changed.
How to reset the alarm: turn on the panel and
wait for the generating set to start. Now press the
button hidden under the small hole in the bottom
left corner (Fig.30 Ref.10) and release it
immediately thereafter.
Wait a couple of minutes before turning the
generating set off.
In certain situations, the data contained in the
microprocessor inside the panel may be altered.
This may be because the battery is very low, or
because the cables used to connect the battery
to the set have too small cross-sections. Altered
processor data may prevent the generating set
from running. In order to restore the generating
set operating efficiency, proceed as follows:
Alarm: the display unit shows random
characters.
Cause: malfunctioning due to low voltage during
start-up (low battery, cable cross-section too
small). Reinitialise the panel.
How to reset the control panel: press the
button (Fig.30 Ref. 10) and while holding it down,
turn on the control panel. Only release the push-
button when 4 zeros (0000) are displayed. The
panel has been reinitialised.
6.7 Automatic Version (optional)
If you wish the start-up batteries to be recharged
automatically in the En 4010 G generating sets, it
is possible to install the ASP (optional) automatic
control panel (fig.32) instead of the manual
control panel.
The elements making it up are:
1 ON/OFF switch for the start-up and switch-off
function
2 Display
3 High temperature indicator
4 Minimum oil level indicator
5 Start-up failed indicator
6 Generator running indicator (flashing)
7 Maintenance request indicator
8 Fuel reserve indicator
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Telair Energy 4010g wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info