627192
7
Zoom out
Zoom in
Vorherige Seite
1/104
Nächste Seite
- 7 -
5. INSTALLATION
WARNING! CARRY OUT ALL INSTALLATION
OPERATIONS AND ELECTRICAL CONNECTIONS WITH THE
WELDING MACHINE COMPLETELY SWITCHED OFF AND
DISCONNECTEDFROMTHEPOWERSUPPLYOUTLET.
THE ELECTRICAL CONNECTIONS MUST BE MADE ONLY AND
EXCLUSIVELY BY AUTHORISED OR QUALIFIED PERSONNEL.
PREPARATION
Unpack the welding machine, assemble the separate parts contained
in the package.
Assembling the return cable-clamp
Fig. E
Assembling the welding cable-electrode holder clamp
Fig. F
HOWTOLIFTTHEWELDINGMACHINE
All the welding machines described in this handbook should be lifted
using the handle or strap supplied if provided for the particular model
(tted as described in FIG. L).
POSITIONOFTHEWELDINGMACHINE
Choose the place to install the welding machine so that the cooling
air inlets and outlets are not obstructed (forced circulation by fan,
if present); at the same time make sure that conductive dusts,
corrosive vapours, humidity etc. will not be sucked into the machine.
Leave at least 250mm free space around the welding machine.
WARNING! Position the welding machine on a at
surface with sufcient carrying capacity for its weight, to
prevent it from tipping or moving hazardously.
CONNECTIONTOTHEMAINPOWERSUPPLY
- Before making any electrical connection, make sure the rating
data of the welding machine correspond to the mains voltage and
frequency available at the place of installation.
- The welding machine should only be connected to a power supply
system with the neutral conductor connected to earth.
- To ensure protection against indirect contact use residual current
devices of the following types:
- Type A (
) for single phase machines;
- Type B (
) for 3-phase machines.
- To comply with the requirements of the EN 61000-3-11 (Flicker)
standard we recommend connecting the welding machine to
interface points of the power supply that have an impedance of
less than:
Zmax = 0.47 ohm (80A).
Zmax = 0.24 ohm (130A - 170A).
Zmax = 0.17 ohm (200A).
- the welding machine does not fall within the requisites of IEC/EN
61000-3-12 standard.
Should it be connected to a public mains system, it is the installer’s
responsibility to verify that the welding machine itself is suitable
for connecting to it (if necessary, consult the distribution network
company).
- Unless otherwise specied (MPGE), the welding machines are
compatible with power generating sets for voltage oscillations up
to ± 15%.
For correct use, the power generating set must be brought to
steady conditions before being able to connect the inverter.
- PLUG AND OUTLET:
- The 230V model is tted at the factory with a power supply cable
and normalised plug, (2P + T) 16A/250V .
It can therefore be connected to a mains outlet tted with fuses
or an automatic circuit-breaker; the special earth terminal should
be connected to the earth conductor (yellow-green) of the power
supply line.
Table (TAB.1) shows the recommended delayed fuse sizes in
amps, chosen according to the max. nominal current supplied by
the welding machine, and the nominal voltage of the main power
supply.
- For welding machines without a plug (115/230V models),
connect a normalised plug (2P + T) - having sufcient capacity-
to the power cable and prepare a mains outlet tted with fuses
or an automatic circuit-breaker; the special earth terminal should
be connected to the earth conductor (yellow-green) of the power
supply line. Table (TAB. 1) shows the recommended delayed
fuse sizes in amps, chosen according to the max. nominal current
supplied by the welding machine, and the nominal voltage of the
main power supply.
WARNING! Failure to observe the above rules will
make the (Class 1) safety system installed by the manufacturer
ineffective with consequent serious risks to persons (e.g.
electricshock)andobjects(e.g.re).
CONNECTIONOFTHEWELDINGCABLES
WARNING! BEFORE MAKING THE FOLLOWING
CONNECTIONS MAKE SURE THE WELDING MACHINE IS
SWITCHED OFF AND DISCONNECTED FROM THE POWER
SUPPLY OUTLET.
Table (TAB. 1) gives the recommended values for the welding cables
(in mm
2
) depending on the maximum current supplied by the welding
machine.
MMAWELDING
Almost all coated electrodes are connected to the positive pole (+)
of the power source; as an exception to the negative pole (-) for acid
coated electrodes.
WELDINGOPERATIONSWITHDIRECTCURRENT
Connecting the electrode-holder clamp welding cable
On the end take a special terminal that is used to close the uncovered
part of the electrode.
This cable is connected to the terminal with the symbol (+).
Connecting the welding current return cable
This is connected to the piece being welded or to the metal bench
supporting it, as close as possible to the join being made.
This cable is connected to the terminal with the symbol (-).
Warnings:
- Turn the welding cable connectors right down into the quick
connections (if present), to ensure a perfect electrical contact;
otherwise the connectors themselves will overheat, resulting in
their rapid deterioration and loss of efciency.
- The welding cables should be as short as possible.
- Do not use metal structures which are not part of the workpiece
to substitute the return cable of the welding current: this could
jeopardise safety and result in poor welding.
6.WELDING:DESCRIPTIONOFTHEPROCEDURE
- It is most important that the user refers to the maker’s instructions
indicated on the stick electrode packaging. This will indicate the
correct polarity of the stick electrode and the most suitable current.
- The welding current must be regulated according to the diameter of
the electrode in use and the type of the joint to be carried out: see
below the currents corresponding to various electrode diameters:
Ø Electrode (mm)
Weldingcurrent(A)
min. max.
1.6 25 50
2 40 80
2.5 60 110
3.2 80 160
4 120 200
- The user must consider that, according to the electrode diameter,
higher current values must be used for at welding, whereas for
vertical or overhead welds lower current values are necessary.
- As well as being determined by the chosen current intensity, the
mechanical characteristics of the welded join are also determined
by the other welding parameters i.e. arc length, working rate and
position, electrode diameter and quality (to store the electrodes
correctly, keep them in a dry place protected by their packaging or
containers).
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Telwin FORCE 125 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info