The three LED's indicate the condition of the battery by to let the gas produced go out.
reading its voltage. The top LED indicates a charged - Check that the level of the electrolyte covers the plates of
battery, with a battery voltage reading greater than or the battery. If these were not covered add distilled water
equal to the voltage setting. The middle LED indicates that and cover them up to 5-10 mm.
_________________________________________________________________________________
the battery is able to receive more current and, lastly, the
bottom LED indicates that the battery is flat.
NOTE: for further details about the indicator see FIG. B
WARNING: USE THE MAXIMUM CAUTION
6-(DISPLAY) Current/Voltage/Time indicator :
DURING THIS OPERATION AS THE ELECTROLYTE IS A
This key can be used to select 3 different indicators:
HIGHLY CORROSIVE ACID.
- ”I”, displays the output current in Amps, in both
_________________________________________________________________________________
”CHARGE”, and “TRONIC” modes.
- ”V”, in this position the display shows the output voltage
- Please remember that the exact charge status of the
over the battery terminals in Volts.
battery can only be determined by using a densimeter
- ”TIME”, in this position the display indicates the length
which allows measurement of the specific gravity of the
of time that has elapsed during “CHARGE” mode, in
electrolyte the following indicate approximate density
minutes.
values for the solute (Kg/l at 20°c):
- The display also shows a set of letters representing the
1.28 = charged battery
current condition /mode (FIG. B).
1.21 = half-charged battery
- In “START-PAUSE” mode the display shows the time
1.14 = flat battery
_________________________________________________________________________________
remaining during the forced pause, in seconds.
7-Selecting Charging Time:
This key is used to select the charging time for the
WARNING: When handling the cables, make sure
“CHARGE” function; the following times are available:
that the “OFF” LED on the front panel is lit up.
2/4/6/10 hours.
_________________________________________________________________________________
In "CHARGE” mode, if the preset time passes before the
- Check the battery voltage and make sure that the settings
end-of-charge voltage is reached, the battery charger will
on the battery charger panel are compatible with the
automatically charge for 2 more hours and then switch off.
specifications for the battery being charged.
8-Potentiometer:
- Check the polarity of the battery terminals: positive for the
This potentiometer is used to set the charge current in
+ symbol and negative for the - symbol.
both "CHARGE" and “TRONIC” modes.
NOTE: if it is impossible to distinguish between the
9-(OFF) Switching off:
symbols, bear in mind that the positive terminal is the one
This key switches the current to the battery/ies ON or OFF.
that is not connected to the vehicle chassis.
WARNING: the battery charger is still powered even
- Connect the red charge clamp to the positive terminal of
when the OFF LED is lit.
the battery (+ symbol).
- Connect the black charge clamp to the vehicle chassis, far
5. INSTALLATION
away from the battery and from the fuel pipe.
SETTING UP (FIG. C)
NOTE: if the battery is not installed in the vehicle, connect
- Unpack the battery charger and assemble the separate
the black clamp directly to the negative terminal on the
parts included in the package.
battery (- symbol).
- Power the battery charger by inserting the power supply
POSITIONING THE BATTERY CHARGER
cable into the mains outlet.
- Position the battery charger for operation, making sure
Position the switch on the back to the ( I ) position.
that it is stable and that there is sufficient ventilation with
- Check the battery voltage and make sure that the settings
no obstructions to air passage through the vents provided
on the battery charger panel are compatible with the
for this purpose.
specifications for the battery being charged. These
- Install the battery charger on a horizontal surface with a
checks should be carried out with the corresponding key
solid base.
in "TEST" mode.
- Set an appropriate current value using the potentiometer
CONNECTION TO THE MAIN SUPPLY
on the front panel.
- The battery charger should be connected only and
exclusively to a power source with the neutral lead
CHARGING
connected to earth.
Press the corresponding key to pass to “CHARGE” mode.
Check that the mains voltage is the same as the voltage of
Position the battery charger to “ON” by pressing the
the equipment.
corresponding key on the front panel.
- Check that the power supply is protected by systems such
Monitor the battery voltage and charge current parameters
as fuses or automatic switches, sufficient to support the
on the display using the “V / I/ TIME” key (FIG.A-6).
maximum absorption of the equipment.
The ammeter will show the charge current (in amps) for the
- The connection to the main supply has to be made using a
battery: at the end of this phase you will see that the value
suitable cable.
shown on the ammeter will decrease slowly to very low
- If you put an extension to the primary cable, the section
values, according to the capacity of the battery and its
should be adequate and, in any case, never less than that
condition.
of the cable supplied.
- You always have to earth the equipment with the
AUTOMATIC CHARGING
yellow/green wire contained in the main cable, indicated
Press the corresponding key to pass to “TRONIC” mode.
by the label ( ), while the other two wires should be
W
Position the battery charger to “ON” by pressing the
connected to the mains.
corresponding key on the front panel.
During this phase the battery charger constantly monitors
6. OPERATION
the voltage over the battery terminals, automatically
BEFORE CHARGING
supplying or cutting off the charge current to the battery as
NB: Before charging check that the capacity of the
necessary.
battery (Ah) which is to be charged, is not inferior to that
Also in this case it is possible to monitor the battery voltage
reported on the data table. (C min).
and charge current on the display using the “V / I / TIME” key.
Follow the instructions, taking great care to respect the
The charge current can be set as illustrated. When it is cut off
order given below.
the display will show the message “END”.
- Remove the caps of the battery charger (if foreseen) so as
- 3 -
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Telwin STARTRONIC 530 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info