658229
2
Zoom out
Zoom in
Vorherige Seite
1/3
Nächste Seite
5
Indoor relative
humidity %
Indoor relative
humidity %
2. Using the + button, set the time zone. The range runs from –
2h to +5h in consecutive 1 hour intervals.
3. Confirm with the SET button and enter the “Time reception
ON/OFF setting”.
TIME RECEPTION ON/OFF SETTING
In areas where no DCF-77 time is possible, you also have the
possibility to deactivate the DCF reception manually (OFF). The
clock will then work as a normal quartz clock. (Default setting is ON).
1. The symbol “ON” will be flashing on the LCD.
2. Use the + button to deactivate (OFF) the time reception
function.
3. Confirm with the SET button and enter the “12/24-Hour
Display setting”.
Note:
If the time reception function is deactivated (OFF) manually, the
clock will not attempt any reception of the radio-controlled time
(DCF time) as long as the time reception OFF function will be
activated (ON) again. If the time reception is deactivated (OFF)
the DCF symbol disappears.
12/24 HOUR TIME DISPLAY SETTING
1. “24h” will be flashing.
2. Press the + button to select the “12h” or “24h” display mode.
3. Confirm with the SET button and to enter the “Manual Time
setting”.
MANUAL TIME SETTING
In case the device is not able to attempt the radio-controlled time
(disturbances, transmitting distance, etc.), the time can be manually
set. The clock will then work as a normal quartz clock.
To set the clock:
1. The hour digits will be flashing on the display.
2. Use the + button to adjust the hours.
3. Press the SET button to go to the minute setting.
4. Use the + button to adjust the minutes. Press and hold the
button in the setting mode for fast running.
5. Confirm with the SET button and enter the “ºC/ºF temperature
unit setting”.
Note:
By a successfully reception of the DCF signal and if the DCF
reception is activated (ON), the manually set time will be overwritten.
During the reception the DCF symbol will be flashing. If the reception
is not successful received, the DCF symbol disappear. The next
attempt will still be held.
°C/°F TEMPERATURE SETTING:
The default temperature is set to °C (degree Celsius). To select °F
(degree Fahrenheit):
1. During “ºC” will be flashing, use the + button to toggle between
“ºC” and “ºF”.
2. Once the desired temperature unit has been chosen, confirm
with the SET button and enter the “
Factory setting
” or press
the MAX/MIN / RESET button to exit the manual setting mode.
FACTORY RESET (FAC)
To reset the temperature station to the factory settings:
1. Press and hold the + button for about 3 seconds to reset the
manual settings to factory settings.
2. Once the factory setting is done, all segments of the LCD will
light up briefly, then the time, indoor temperature and humidity
will be displayed.
Important:
During factory setting, all signals from the transmitters are lost.
In order to receive the transmission signals from the
transmitters, please refer to “Setting up” above to set the
initial reception signal again.
TO EXIT THE MANUAL SETTING MODE
To exit the manual setting mode anytime during the manual setting,
press the MAX/MIN / RESET button.
OUTDOOR TRANSMITTER AND POOL SENSOR
SEARCH MODE
If the transmitters are lost due to disturbances, interferences,
transmitting distance, etc., a manual transmitter search can be
started.
1. Press the + button to select the transmitter.
2. “LEARN” appears in the display of the selected transmitter.
3. Press the SET button to start the search.
4. The reception symbol will be flashing.
5. As soon as the transmitter is found, the temperature appears
and the reception symbol stays in the display.
INDOOR TEMPERATURE / HUMIDITY AND DEW POINT
DATA
The indoor temperature and humidity are detected automatically and
displayed on the second section of the LCD.
To display the dew point temperature, press the MAX/MIN / RESET
button 3 times.
DEW POINT appears in the display.
The device will automatically quit the dew point mode if no button is
pressed for a lengthy period (30 seconds) or press the MAX/MIN /
RESET button again to return to the actual display.
Note:
The dew point value is based on calculation of the indoor
temperature and humidity data.
OUTDOOR TEMPERATURE AND POOL
TEMPERATURE
The last two LCD section shows the outdoor temperature, pool
temperature and reception signals.
TOGGLING AND RESETTING THE MIN/MAX DATA
TO VIEW THE MIN/MAX DATA AND DEW POINT
1. Press the MAX/MIN / RESET button the indoor temperature
and humidity and the outdoor temperature and pool
temperature (MIN) appear.
2. Press the MAX/MIN / RESET button again the maximum
indoor temperature and humidity and the outdoor temperature
and pool temperature (MAX) appear.
3. Press the button MAX/MIN / RESET again the dew point
appears (DEW-POINT).
4. The instrument will automatically quit the MAX/MIN mode if no
button is pressed for a lengthy period (30 seconds) or press
the MAX/MIN / RESET button again to return to the actual
display.
TO RESET THE MIN/MAX DATA
Press and hold MAX/MIN / RESET button for 3 seconds to reset
all the indoor, outdoor and pool values to current values at the
same time.
TRANSMITTERS
The outdoor data are measured and transmitted every 10 seconds.
The range of the transmitter is may be affected by the outdoor
temperature. At cold temperatures the transmitting distance may be
decreased. Please bear this in mind when placing the transmitters.
868 MHz RECEPTION:
If the outdoor data are not being received within three minutes after
setting up (or outdoor display always show “- -. -” in the outdoor
sections of the temperature station during normal operation), please
check the following points:
1. The distance of the temperature station or transmitters should
be at least 2 meters away from any interfering sources such
as computer monitors or TV sets.
2. Avoid placing the transmitters onto or in the immediate
proximity of metal window frames.
3. Using other electrical products such as headphones or
speakers operating on the 868MHz-signal frequency may
prevent correct signal transmission or reception. Neighbors
using electrical devices operating on the 868MHz-signal
frequency can also cause interference.
Note:
When the 868MHz signal is received correctly, do not re-open the
battery cover of either the transmitter or temperature station, as the
batteries may spring free from the contacts and force a false reset.
Should this happen accidentally then reset all units (see Setting up
above) otherwise transmission problems may occur.
The transmission range is around 100 meters from the temperature
station to the outdoor transmitter (in open space) and 25 meters to
the pool sensor (in water). However, this depends on the surrounding
environment and interference levels. If no reception is possible
despite the observation of these factors, all system units have to be
reset (see “Setting up above).
POSITIONING THE TEMPERATURE STATION
The temperature station comes attached with a folding stand, which
provides the option of table standing or wall mounting the unit. Before
wall mounting, please check that the outdoor temperature can be
received from the desired locations.
Foldout table stand:
The foldout table stand leg is located on the
backside. Pull the stand out from the bottom
center edge of the temperature station, below
the battery compartment. Once the foldout table
stand is extended, place the temperature station
in an appropriate location.
To wall mount:
1. Fix a screw (not supplied) into the desired
wall, leaving the head extended out by
about 5mm.
2. Place the temperature station onto the
screw, using the hanging hole on the
backside. Gently pull the temperature station down to lock the
screw into place.
POSITIONING THE OUTDOOR TRANSMITTER
Mount the transmitter at a sheltered place. Avoid
direct rain and sunshine.
The outdoor transmitter is supplied with a holder
that may be attached to a wall with the two screws
supplied. The outdoor transmitter can also be
position on a flat surface by securing the stand to
the bottom to the outdoor transmitter.
To wall mount:
1. Secure the bracket onto a desired wall
using the screws and plastic anchors.
2. Clip the outdoor transmitter onto the
bracket.
Note:
Before permanently fixing the outdoor
transmitter wall base, place all units in the
desired locations to check that the outdoor
temperature readings are receivable. In event that the signal is not
received, relocate the remote outdoor transmitter or move them
slightly as this may help the signal reception.
POSITIONING THE POOL SENSOR
Place the pool sensor in any pool or pond to detect the water
temperature.
Note:
In event that the signal is not received,
relocate the remote pool sensor or
move it slightly as this may help the
signal reception.
CARE AND MAINTENANCE
Clean the instrument and the transmitters with a soft damp
cloth. Do not use solvents or scouring agents. Protect from
moisture.
Remove the batteries if you do not use the product for a
lengthy period.
BATTERY REPLACEMENT
Replace the batteries of the temperature station when the
battery symbol appears in the indoor values display.
Replace the batteries of the outdoor transmitter when the
battery symbol appears in the outdoor temperature display of
the temperature station and/or in the display of the outdoor
transmitter.
Replace the batteries of the pool sensor when the battery
symbol appears in the pool temperature display of the
temperature station and/or in the display of the pool sensor.
Please note:
When the batteries are changed, the contact between outdoor
transmitter, pool sensor and basic station must be restored –
so always insert new batteries into the three devices or start a
manual transmitter search.
The manuals settings will remain unchanged.
MALFUNCTION
Problems Troubleshooting
No indication on
the temperature
station
Ensure batteries polarity are correct
Change batteries
No transmitter
reception
Display "---"
Start a manual transmitter search
Check batteries of external
transmitters (do not use
rechargeable batteries!)
Restart the transmitters and
temperature station as per the
Temperature
transmitter
reception
signal
Outdoor
temperature
in °C or °F
Indoor
temperature
in °C/°F
Dew point
temperature
in °C/°F
Minutes
(flashing)
Hours
(flashing)
Flashing
Flashing
Flashing
Flashing
Pool
temperature
in °C or °F
Pool sensor
reception
signal
“LEARN” icon
Reception
signal flashing
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für TFA 30.3053.IT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von TFA 30.3053.IT

TFA 30.3053.IT Bedienungsanleitung - Deutsch - 3 seiten

TFA 30.3053.IT Bedienungsanleitung - Holländisch - 3 seiten

TFA 30.3053.IT Bedienungsanleitung - Französisch - 3 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info