COMFORT CONTROL – Thermo-Hygrometer
Placing or hanging up the unit:
A circular opening is provided on the backside of the unit for
hanging on the wall. To place the unit in the standing position use the
stand supplied with the unit. Since the humidity level within rooms can
vary greatly according to the location, mount the unit so that it will moni-
tor the conditions in a location likely to be subject to the most problems.
Care and maintenance
Clean your instrument with a soft damp cloth. Do not use solvents or scour-
ing agents
Remove the batteries if you do not use it for a long period of time
Keep the instrument in a dry place.
Battery replacement
Remove the stand if necessary. Lightly push the silver battery lid on the
front down and open the battery compartment. Replace the batteries
(2 x 1.5 V AA). Do not use rechargeable batteries. Close the battery com-
partment again.
Troubleshooting
Problems Solution
No indication Observe correct polarity when inserting the
batteries
Change batteries
Incorrect display Change batteries
Press RESET button
If your device fails to work despite these measures contact the supplier from
whom you purchased it.
Waste disposal
This product has been manufactured using high-grade materials and compo-
nents which can be recycled and reused.
Never dispose of empty batteries and rechargeable batteries in
household waste.
As a consumer, you are legally required to take them to your
retail store or to appropriate collection sites depending on
national or local regulations in order to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the EU Waste Elec-
trical and Electronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste. The
user is obligated to take end-of-life devices to a designated col-
lection point for the disposal of electrical and electronic equip-
ment, in order to ensure environmentally-compatible disposal.
1110
COMFORT CONTROL – Thermo-Hygrometer
Do not turn the heating completely off when going out.
Ventilate in all weather conditions, even if it's raining.
Open the windows for a short time (room airing). A partially open win-
dow, for instance in the tilted position, does not have the desired effect,
wastes heating energy and can even promote the formation of mould.
If the room air is too dry, particularly in wintertime, then electrical air
humidifiers are recommended, since airing at low outside temperatures
will tend to decrease the humidity further.
Duration of airing:
A few minutes are mostly sufficient. Check the value indicated on your
COMFORT CONTROL!
Operation:
Startup:
Lightly push the silver battery lid on the front down and open the bat-
tery compartment. Remove the battery safety strip. Close the battery
compartment again.
Remove the protective foil from the display. The unit is now ready to use.
Display:
The left display shows the indoor relative humidity, the middle row the
room temperature and the right row the dew point. The temperature
unit can be changed from °C to °F by the °C/°F-button at the backside.
Humidity alarm:
Select the humidity alarm value 65, 60 or 55 % by the sliding switch at
the backside.
If air humidity exceeds the selected value and there is a risk of mould for-
mation, the up-arrow and the red lamp will flash and an alarm signal will
sound for 1 minute. The alarm can be turned off by pressing any button.
When air humidity falls below the selected value the up-arrow and the
red lamp will stop flashing. The up-arrow remains on the LCD showing
that humidity exceeded the preset value at least once in the past. Press
any button and the up-arrow will disappear. The acoustic signal can be
muted by operating the sliding switch on the rear-side.
MIN / MAX temperatures:
Press the MIN / MAX button and the highest temperature and humidity is
displayed since the last reset.
Press the MIN / MAX button again, the display shows the lowest tempera-
ture and humidity since the last reset.
To go back to the present values, press the MIN / MAX button once more.
Press the RESET button, while the maximum and minimum values are dis-
played to clear the recorded maximum and minimum readings and the
actual values appear.
TFA No. 30.5011 Anleitung_02_13 04.02.2013 10:06 Uhr Seite 6
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für TFA 30.5011 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info