16. Specifications
Basic station
Measuring range indoors
Temperature 0 °C… +50 °C (+32 °F …+122 °F)
Humidity 1 … 99%
Power consumption Batteries: 3 x 1,5 V AAA (not included)
Power adapter: 230 V AC / 5.0 V DC (included)
USB output 5 Volt … 1 Ampere
Dimensions 175 x 26 (58) x 125 mm
Weight 290 g (instrument only)
Outdoor transmitter
Measuring range outdoors
Temperature -40 °C… +60 °C (-40 °F …+140°F)
Humidity 1 … 99%
Range max. 60 m (free field)
Transmission frequency 433 MHz
Maximum radio-frequency power < 10mW
Transmission time 50 seconds
Power consumption Batteries: 2 x 1,5 V AAA (not included)
Dimensions 45 x 20 x 108 mm
Weight 45 g (instrument only)
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going
to print and may change without prior notice. The latest technical data and information about your product can be found by entering
your product number on our homepage.
EU declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 35.1136 is in compliance with Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the following internet address:
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Germany 09/16
13. Care and maintenance
Clean the devices with a soft damp cloth. Do not use solvents or scouring agents.
Remove the batteries and pull out the power adapter of the socket, if you do not use the products for a long
period of time.
Keep the devices in a dry place.
13.1 Battery replacement
Change the batteries of the outdoor transmitter, when the battery symbol appears on the display of the out-
door values.
Change the batteries of the basic station, when the battery symbol appears on the display of the indoor values.
Please note: When the batteries are changed, the contact between outdoor transmitter and basic station
must be restored – so always insert new batteries into both devices or start a manual transmitter search.
14. Troubleshooting
Problems Solution
No indication at the basic station Operation with mains adapter:
Connect the basic station to mains adapter
Activate backlight permanently
Control the power adapter
Operation with batteries:
Ensure that the batteries polarity are correct
Press any button to activate the backlight briefly
Change the batteries
No DCF reception Press and hold the +/RCC button for three seconds and start the initializa-
tion manually
Wait for attempted reception during the night
Choose another place for your product
Manual setting of the clock
Check if there is any source of interference
Restart the basic station according to the manual
No reception of the No outdoor transmitter is installed
outdoor transmitter Check batteries of external transmitter
Indication “---” (do not use rechargeable batteries!)
for channel 1/2/3 Restart the outdoor transmitter and the basic station according to the
manual
Start the outdoor transmitter search manually according to the manual
Choose another place for the outdoor transmitter and/or the basic station
Reduce the distance between the outdoor transmitter and the basic station
Check if there is any source of interference
Incorrect indication Change the batteries
15. Waste disposal
This product has been manufactured using high-grade materials and components which can be recycled and
reused.
Never dispose of empty batteries and rechargeable batteries in household waste. As a consumer, you
are legally required to take them to your retail store or to an appropriate collection site depending
on national or local regulations in order to protect the environment.
The symbols for the heavy metals contained are: Cd=cadmium, Hg = mercury; Pb=lead
TFA_No. 35.1136_Anleitung_09_16 20.09.2016 10:12 Uhr Seite 11
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

tfa-35.1136

Suche zurücksetzen

  • Wie muss ich bei 35/2012 v000 die Batterien wechseln Eingereicht am 9-9-2019 17:58

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für TFA 35.1136 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info