F. Adjustable wall bracket N. Roofing sheet, sloping at 5-30°
G. Concentric pipe O. Roof pass-through
H. Universal mounting plate P. Lead roof plate 20-45°
12.1 Possibilities for connecting concentric flue system
Indirect wall pass through (see page 23 diagrams 1 and 2).
Always fit a length of X=1 metre vertical on the apparatus and then directly after this a bend of 90° with a length
Y (min) wall pass through on this. If required the horizontal part can be extended to 5 metres plus wall pass
through (Y max) .
Note: For propane appliances 4metres plus wall pass through applies (Y max).
This horizontal slope must never
be exceeded.
Roof pass through without slope ( see page 23 diagram 3).
You can use a direct pipe layout without a slope for a maximum length of X=12 metres (excluding the roof vent
flange) measured from the connection on the unit. The minimum length is 2 metres. You can have a flue terminal
at every position on the roof face (both flat and sloping); the flue tube and combustion air supply are located in
the same pressure area. For 2 metres and longer a restriction plate must be used for all gas types.
Roof pass through with slope 45° ( see page 23 diagram 4).
Always fit a length of X=1 metre vertically on the unit. Next, continue building up the flue pipe using 2 45º
bends (the calculation length for each bend is 1 metre) until you have reached the maximum pipe length of 12
metres (including bends excluding roof pass through). The minimum length is 2 metres. You can have a flue ter-
minal at every position on the roof face (both flat and sloping); the flue tube and combustion air supply are lo-
cated in the same pressure area. For 2 metres and longer a restriction plate must be used for all gas types.
Roof pass through with slope 90° ( see page 23 diagram 5).
Always fit a length of X=2 metres vertically on the unit. Next, continue building up the flue pipe using 2 90°
bends (the calculation length for each bend is 2 metres) until you have reached the maximum pipe length of 12
metres (including bends, excluding roof pass through). The minimum length is 3 metres. You can have a flue ter-
minal at every position on the roof face (both flat and sloping); the flue tube and combustion air supply are lo-
cated in the same pressure area. Take into account a maximum horizontal layout of Y=4 metres (measured be-
tween bends) and also ensure sufficient gradient. For 2 metres and longer a restriction plate must be used for all
gas types.
12.2 Construction of concentric flue system
Assembly instructions are given below:
Mounting using an exterior wall duct
The outlet can also be installed above the exhaust in the wall (always one metre vertical first), take into account
obstacles according to environment. The (local) Building Regulations will provide the required guidelines in re-
lation to this matter. Also, ensure that the wind pressure on the flue terminal here is not too extreme either (for
example, in very narrow lanes or alleys) since this may negatively influence the unit efficiency. Provide a recess
in the exterior wall with of around 155 mm (in a flammable wall have 50mm of extra space round the outer pipe)
and fix the wall pass through with the wall plate to the inner side of the wall. The wall plate of the exterior wall
duct must be sealed sufficiently against the wall on the outside; this is in connection to there being leaks of mois-
ture and/or flue gas into the living space. The flue should be cased if necessary. Sufficient fireproof measures
must also be taken when the flue is being mounted along flammable materials. Determine the position of the ap-
paratus and the outlet and begin the construction of the flue with the connection on the apparatus, pay attention to
the direction of installation. The inner flue must be installed for draining. Connect the elements by using clamp-
ing straps. Fit a bend of 90° directly on the wall pass through and make the connection with the elements on the
apparatus. Ensure that the gastightness of all connections is correct. A fitted pipe can be used in between the
bends or when making the connection to the unit. If necessary use wall brackets to support the flue. Provide a re-
cess in the exterior wall of around 155 mm (in a flammable wall have 50mm of extra space round the outer pipe)
and fix the wall pass through with the wall plate to the inner side of the wall. The wall plate of the exterior wall
duct must be sealed sufficiently against the wall on the outside; this is in connection to there being leaks of mois-
ture and/or flue gas into the living space.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Thermocet Coventry S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info