After completing any work: Test for leaks and check operation.
9.6 Connecting to the mains supply
The regulation equipment is fitted with an electronic control. Take into account the length of the cable
when connecting to a power socket.
9.7 Chimney
If it is connected to a chimney that had previously been connected to a wood-fuelled fire, than the flue
should be thoroughly and professionally cleaned as dirt can still become dislodged from the chimney when
used with gas. The chimney will need to be cleaned again after a couple of months.
9.8 Warning.
* Only install the unit in a well-ventilated room.
* The gas unit is only suitable for installation in a non-flammable, fire resistant mounting.
* This is an open fire so you should not place any light flammable articles nearby: care should be taken with ny
lon clothing.
* The exhaust gas outlet should have a minimum diameter that corresponds to the size of the connection.
* Protect all pipes (electric/gas) through a wall duct using a pvc tube and so forth.
* If there is a valve or slider in the exhaust gas outlet that allows the outlet to be fully or partially closed, this
should be locked in an open position using a protector connected to the control.
10. ELECTRICAL AND GAS CONNECTION
10.1 Electrical connection.
The regulator is composed of various components which should be fitted in the
correct manner. You need to provide the following:
* 230 V AC, 50 Hz power supply positioned near to the gas block fire.
* The plug and the power socket should be within reach at all times. Position the main components, namely the
control cabinet and the gas regulator combination in a place that is easily accessed. The maximum permitted
ambient temperature for all of these components is 60° C. The regulation box is simple to mount, for instance
on a wall. Remove the cover plate from the regulation box by unscrewing the 2 cover plate screws. The regu
lation box can be positioned on the assembly slots in the bottom of the regulation box.
10.2 Order of installation: electrical connections.
* Connect according to local regulations.
* Determine the position for the control box and the gas regulation combination (pay attention to the maximum
length of the wire harness).
* Check that the wire harness from the gas block is connected to the Modu box.
* The ignition cable should be passed through separately on its own. (excess sparking)
* Determine the position of the infra-red receiver (the lens should remain visible to the remote control)
* Insert the power cable into the wall socket.
* If used, connect the open position protector or GTP as shown in the wiring diagram. (See page 21).
* Ensure that the ground wire is properly connected. Without this connection, ionization current protection is
not possible.
* For connections and attachments for the basic gas regulation combination (See page 22).
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Thermocet Transparente 140 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Thermocet Transparente 140

Thermocet Transparente 140 Bedienungsanleitung und Installationsanweisung - Holländisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info