13. MAINTENANCE FAULT CHECKLIST.
Please note: whenever possible, turn off the gas supply and power supply during maintenance activities.
Maintenance activities should be performed by a qualified fitter.
Close the gas tap while maintenance activities are being performed
Inspect
Works OK
1 General inspec-
tion
a The main burner should ignite smoothly (within several seconds) and not give a bang sound due
to delayed ignition. Go to number 7 if the ignition appears to be delayed.
b Check the appearance of the flame. The flame should not flicker. It should turn yellow after ap-
proximately 15 minutes; go to number 7 if the flame is blue in colour.
c Check for excessive soot deposits on decorative parts. Go to number 7 if there is excessive for-
mation of soot.
2 Decorative parts
(logs/pebbles etc.)
and (pilot) burner
a remove decorative parts and clean the burner (be careful with ceramic burners!) with a vacuum
cleaner.
b inspect decorative parts for damage/cracks/discolouration and clean with a soft brush if required.
c check if the burner cover is intact and free of corrosion. Replace the burner if required.
d after completing the inspection: replace decorative parts, exactly as stipulated by the manufac-
turer. Ensure the pilot burner is free from obstructions!
e check if the pilot flame protection is intact (if applicable).
f check the piezo for sufficient sparking power, and ensure that the ignition cable is free from
metal parts/electrical parts.
3 Ignition and op-
eration of the
main burner
a check if the injector head is free from dirt.
b check if the primary ventilation opening in the main burner is free from dirt.
c
Check the burner and whether it is in a good position in relation to the pilot burner. (if applica-
ble)
d check that the burner is firmly positioned and cannot move.
e check if the pilot burner is burning well, with a steady blue flame
f
check whether the burner is uniformly igniting across the entire surface and without any signifi-
cant delay.
g check if the appearance of the flame is uniform and stable.
h check the initial and burner pressure. Do not forget to close the pressure measuring points.
i check whether the gas control parts are intact, and that plastic parts for example, have not
melted.
j
check electrical wiring for damage and ensure that wires are positioned away from the hot areas
of the unit.
4 Installation a
check whether there is a sufficient distance between the unit and any flammable furniture for
instance.
5 Flue tube/air sup-
ply
a where possible, inspect the general state of the exhaust/supply system and check for blockages /
leaks / corrosion.
b check the outlet, which should be free from dirt and blockages.
c specifically check for leaking cement borders, etc.
6 Remote control a check for correct functioning of the remote control.
7 Ventilators (if
present)
a clean the ventilators and check that they function correctly.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Thermocet Transparente 140 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Thermocet Transparente 140

Thermocet Transparente 140 Bedienungsanleitung und Installationsanweisung - Holländisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info