2.1 Connection the gas lines
You can determine where the gas pipes will be placed, depending on the positioning of the appliance.
Ensure control equipment is not twisted during installation and there is no excessive tension.
Accessibility of various connection pointsin relation to components need to be maintained. After installation,
check the connections for gas leakage. Use a 3/8“ gas tap in the main gas supply.
Ensure the gas pipes are dirt-and sand-free. The gas connection should only be done without any excessive
tension in the tubes etc. This prevents any damage occurring to the gas control equipment.
2.2 Preparation and installation (see APPENDIX 5)
* Remove the packaging and check the unit for possible damage.
* Please note: place the unit on a stable surface. Attention; Do not place the unit on its back/side!
* Place the unit at the installation location
* you can use the lifting brackets supplied with each appliance(1).
* The window should now be removed in order to take the additional parts out of the unit.
* Remove the decorative frame on the bottom side of the window.
* Loosen the screws holding the bottom and top glass holders (2).
* Place the suction cup (s) in the middle of the glass-panel and remove the panel by GENTLY moving this
first upwards and then the lower edge of the panel very carefully and slowly pulling toward you (3 and 4).
Then place in a safe place where the window can not be broken or damaged. If the removed glass panel
shown damage (scratches and / or damaged edges) do not use the glass panel and alerting the supplier.
* Next, take all the packaged components out of the unit and check to make sure they are not damaged
or broken.
* Situate the unit (see APPENDIX3 as an example of an installation location) in your chosen installation location.
The device must be attached directly to the rear wall (mounting material not included) (5).
* The legs of the device can be adjusted. (Min 150 Max 455) (5)
* The adjustable feet allow to adjust the device more refined.
* Build the gas cassette in the self-assessed surround/casing. The distance between the gas cassette and
the unit is determined by the cable lengths of which control cabinet to the pilot burner and the gas control etc.
Max.1500 mm. Before building in the gas cassette first install the gas control inside, see 2.3.
* Install the supplied convection grilles at least 50 cm below the ceiling (see APPENDIX 2) on the appropriate
wall. A lowered ceiling inside the whole structure could be a possible solution in the event of a very high
space inside this structure.
2.3 Installing gas control GV60 (see APPENDIX 6)
The complete gas control is fitted under the gas unit. The gas valve including the burner control must
be fitted by the installer in the gas cassette. The step by step procedure:
* After the window is taken away and parts inside the gas fire are taken out; place the complete
gas fire care fully on the backside(1). You can use the wooden pallet to support the gas fire.
* Cut the binders and CAREFULLY loosen and unroll the various lines and cables (2).
* Remove the screw holding gas valve bracket (3) and carefully take away the gas valve and move it to
the side of the gas fire where you want to install the gas cassette
* Install the Gas valve + bracket inside the gas cassette, and secure it with the two winged nuts
at the position as indicated ( 4,5,6).
* Place the entire gas cassette into the surround/casing of the gas fireplace. Be aware of the maximum
distance between gas fire and gas cassette limited by the length of thermocouple etc.(7)
* Make sure the tubes, ignition cable and thermocouple without tension and sharp bends
provided, this must be avoided at all times. Make sure the spark plug cable is free from metal parts (8).
NOTICE
Before installing the device it is recommended to first read Chapter 7
"Concentric flue system"
2. PLACING THE APPLIANCE
NOTICE
Temperature of the exhaust grilles could reach over 100 ° C. Caution is therefore needed.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Thermocet Trimline 100 DB Tunnel - 1135 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Thermocet Trimline 100 DB Tunnel - 1135

Thermocet Trimline 100 DB Tunnel - 1135 Installationsanweisung - Holländisch - 27 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info