607243
13
Zoom out
Zoom in
Vorherige Seite
1/49
Nächste Seite
Page.13
7.3 Installation instructions regarding existing flues.
Instructions
The flue gas exhaust system falls within category C91 and must be built in accordance with national rules and
regulations and the instructions of the manufacturer, as specified in the documentation and installation
instructions.
This means, among other things, that the chimney pass-through must not be smaller than 150 mm round / square,
but no larger than 200 mm, and not ventilated by grilles etc. In the case of larger chimney pass-throughs, a
flexible hose of around 150 mm may possibly be used in combination with a flexible hose of around 100 mm, as
described below. For other situations, you should consult your supplier / manufacturer.
7.4 Parts
Check all parts for damage before commencing the installation. You will require the following parts for
converting a brickwork duct to a concentric duct connecting to a CC duct system (see page 14 fig. A):
1. Fireplace
2. Concentric duct 100-150 or 130-200 mm
3. Mounting plate inside, square 300 mm
4. Adapter, single-wall
5. Parkers (4 x)
6. Flexible hose, stainless steel 316 L, single-wall and round 100 /107
7. Hose bracket, stainless steel
8. Existing brickwork duct
9. Mounting plate / connecting piece on the roof, square 300 mm
10. Clamping strap
11. Roof pass-through, standard
Note: The renovation/sanitation set consists of parts 3, 4, 5, 7, and 9.
7.5 Installation (See page 14, figure A)
· Guide the flexible hose (6) through the existing duct (8).
· Attach the adapter (4) to the bottom of the flexible hose and secure this in place using 2 parkers (5).
· The mounting plate (3) is adjustable, slide / fix it on to the outer pipe and then mount it against the ceiling
(airtight).
· Shorten the flexible hose to approximately 50 mm above the chimney coping plate.
· Attach the mounting plate / connecting piece to the flexible hose on the roof (9), clamp it with a hose bracket
(7) and secure it in place using a parker (5).
· Attach the mounting plate / connecting piece to the chimney coping watertight on the roof (9) using silicone
sealant and stainless steel screws.
· Install the roof pass-through (11) and secure it in place using the supplied clamping strap (10).
· Position the unit (1) in accordance with the instructions of the unit manufacturer.
· Always install a minimum of 1 metre of concentric duct type CC/US 100-150 (2), or 130-200 mm with
reduction to 100-150 mm.
7.6. Cleaning and maintenance.
The unit must be cleaned and checked every year by your dealer. The Concentric flue system must be cleaned
every 2 years.
Carry out the checks in accordance with the inspection list on page 22.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Thermocet Trimline 10038 Panorama-Corner wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info