1.1 General instructions
* The gas fireplace must be installed, connected and inspected as a balanced flue fire by a qualified fitter,
according to national, regional, and local standards and regulations.
* The flue system and the terminals in the outer wall or roof face must also meet the requirements
outlined in the applicable standards and regulations.
* The temperature of the walls and shelves near the side and back of the unit may not be more
than 80°C higher than the temperature of the environment.
* The unit has been approved in combination with the THC CC Ø100 mm - Ø150 mm and
Ø130 mm - Ø200 mm , in accordance with European CE standards for gas fires, and may therefore
only be applied with this system.
* The product needs to be serviced and inspected by the fitter for local gas distribution as indicated on
the identification plate.
* The instructions are only applicable if the relevant country code is stated on the unit. If this is not the
case, the gas technical information for the relevant country needs to be consulted and modifications
discussed with the manufacturer.
* There will be air in the gas pipes when the unit is first used. The gas pipes therefore need to be purged first.
* Ignite the fire according to operating instructions and check whether the burner flame is uniform.
After the unit has been used for the first time, you should remove any deposits resulting from
Running/burning in the paint, using a glass cleaner for heaters.
Distance to flammable materials:
* With respect to the front, side and top of the unit, a distance of 1200 mm needs to be kept between
the unit and: curtains, floor covering, upholstery and fabrics, and/or other flammable material unless
stated other wise in these instructions.
Distance to non-flammable materials:
* The unit needs to be placed a minimum distance of 25 mm from the wall unless stated otherwise in
these instructions.
The installation should be performed only by an authorized gasfitter
NOTICE
1. INSTALLATION INSTRUCTIONS
WARNING
Gas fires become hot when they are in operation. After installing the appliance the glass surface
is considered active zone. The glass surface can become very hot.!
Attention! Accordingly, care should be taken, for example children and needy in the vicinity of
burning fires are banned. Gas fires must not be on or against flammable materials are placed
(curtains etc.).
Never install the unit against or within a flammable wall!.
Construction material for fireplaces and mantles etc. or built-in situation, must be made of
non-combustible material. This also applies to floors and ceilings. Never use flammable
materials near the unit in compliance with the above requirements.
If in doubt, consult your dealer
NOTICE
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Thermocet Trimline 140 DB Tunnel - 1149 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Thermocet Trimline 140 DB Tunnel - 1149

Thermocet Trimline 140 DB Tunnel - 1149 Installationsanweisung - Holländisch - 27 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info