600941
13
Zoom out
Zoom in
Vorherige Seite
1/37
Nächste Seite
13
6. Boiler operation
Description of the control panel:
Control panel is simple and intuitive and displays the boiler functions.
The panel uses colour-coding and graphical division of the heating and DHW preparation sections. LEDs
positioned between the buttons for setting the temperature higher/lower (up/down arrows) are turned on if the
particular mode is selected (i.e. either the DHW
2
preparation mode or the heating water mode marked TOP).
If the display shows any other variable, pressing one of the , buttons (1) displays the heating water
temperature (the LED “°C” TOP is turned on).
If the display shows any other variable, pressing one of the , buttons (2) displays the DHW temperature
(the LED “°C” TUV is turned on).
Changing the value of the desired variable: When the heating water temperature is displayed (the LED “°C”
TOP is on), the first pressing of one of the heating temperature setting buttons displays the setting for the
required value of this temperature. This is indicated by the flashing of LED “°C” TOP. Required value can be
changed within the ranges defined in the service menu. The set value becomes automatically registered in the
memory after 15 seconds of inactivity (measured after the last button was pressed).
The required DHW temperature is set in a similar fashion (by the DHW temperature setting buttons).
The five LEDs below the main display show the variables which are currently set or indicated on the 3-digit
display:
- if the LED °C (TOP or TUV) is on, the display shows the temperature of water in the heating or DHW
circuits
- if the LED “
IN
/
OUT
°
°°
°C ” is on, the display shows the temperature of the outdoor or room temperature sensors
- if the LED “HDO” is on, the MRC signal is activated and the boiler produces heat in the low tariff
- if the LED “bar” is on, the display shows the pressure in the TOP system in bars
Automatic control elements (user access):
1. Buttons for displaying heating temperature settings , (1) higher/lower, additionally, if
selected, browsing through the service MENU
2. Buttons for displaying DHW temperature settings , (2) - higher/lower, the flashing value of
the selected variable can be also changed in the menu)
3. Heating on/off button O/I (MENU) (3) (press shortly), open the MENU (press for more than 2
seconds), exit the MENU (press shortly)
4. DHW heating on/off button O/I (ENTER) (4) (press shortly), ENTER (press shortly only in the
MENU)
5. SELECT – main display selection button (SELECT) (5):
temperature (according to the menu and selected option)
• water pressure (bar)
• output (kW)
• error messages (last error)
• heating mode
6. 3-digit 7-segment LED display
7. 7 LED indicators for the selected functions
2 The Czech abbreviation for DHW is TUV: translator's note.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Thermona THERM EL 45 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info