7
5 - MAINTENANCE (See General Warnings 9, 11,15 and 17 p.4 & 5)
CAUTION: Before removing the plastic cover, make sure the power is turned off to avoid any risk of injury or electric
shock
▪ User maintenance: Operates once a month the discharge of the water safety device to prevent scaling and
verify that it is not blocked. If this is not done, damage may be caused and the guarantee invalidated.
▪ Maintenance by a qualified person:
1/ Remove the scale sludge. Do not scrape or hammer the lime scale deposited on the casing, as this may damage
the lining.
2/ Change the magnesium anode every 2 years or when its diameter is lower than 10 mm.
3/ Changing the shielded heating element or the anode requires the water heater to be drained and the joint changed.
4/ Draining (depending on models): Switch off the power and water supply and open the hot water tap before carrying
out the draining operation.
5/ Refit the heating element and tighten the screws smoothly (opposite screws in sequence), check for leaks the next
day and tighten if required.
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or
its service agent
Spare parts list: thermostat, thermal circuit breaker, joint, heating element, pilot light, the magnesium anode, the
connection cable. The guarantee requires genuine manufacturer’s parts to be used.
6 - SCOPE OF THE GUARANTEE
The water heater must be installed, used and maintained according to best practice and conform to the standards in
force in the country in which it is installed and to the instructions contained in this document.
In the European Union this appliance is covered by the statutory guarantee accorded to consumers in accordance with
directive 1999/44/CE. This guarantee comes into force when the appliance is delivered to the consumer. In addition to
the legal guarantee, certain items are covered by an extra guarantee relating only to the free exchange of the tank and
of components accepted as defective. It does not include the cost of replacement or carriage. Refer to the table
below. This commercial guarantee does not affect your statutory rights. It applies within the country where the product
was acquired, provided it is also installed in the same country. The dealer must be informed of any damage before the
product is exchanged under guarantee and the appliance will remain available for inspection by experts from the
insurance company and the manufacturer.
To claim under guarantee, contact your installer or dealer. If necessary, contact: ATL INTERNATIONAL
Tel:(33)146836000, Fax (33)146836001 58 avenue Général Leclerc 92340 Bourg-la-Reine (France) who will inform you
of what you should do. The guarantee applies only to examine products which are accepted as faulty by the company
underwriting the guarantee. It is essential that products should be retained for inspection by them. Exclusions: Wear
parts: magnesium anodes….Equipment which cannot be assessed (access difficult for repair, maintenance or
assessment). Equipment exposed to abnormal environmental conditions: frost, bad weather, water which is abnormally
aggressive or outside drinking standards, electrical supply with large spikes. Equipment installed without observing
current standards in the country of installation: the absence or incorrect fitting of safety devices, abnormal corrosion due
to incorrect water fitments (iron/copper contact), incorrect earthing, inadequate cable thickness, non-observance of the
connection drawings shown in these instructions. Equipment not maintained in accordance with these instructions.
Repairs or replacement of parts or components in the equipment not carried out or authorised by the company
responsible for the guarantee. Changing a component does not extend the life of the guarantee.
CAUTION: To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and
pressure protective equipment supplied with the water heater (pressure relief devices). Install the valve into an opening
provided for this purpose in the water heater, and orient it or provide tubing so that any discharge from the valve will exit
only within 15cm above or at any distance below the structural floor and cannot contact any live electrical part. The
discharge opening must not block or reduce in size under any circumstances.
For specific conditions outside European union, please refer to local guarantee cards