45183
2
Zoom out
Zoom in
Vorherige Seite
1/66
Nächste Seite
DECLARATION OF CONFORMITY
According to
Low voltage Directive 73/23/EEC and
The Amendment to LVD 90/683/EEC
EMC Directive 89/336/EEC
Automotive Directive 72/245/EEC and
The Amendment 95/54/EC
GAS Directive 90/396/EEC
CE Marketing Directive 93/68/EEC
Type of equipment Absorption Refrigerator
Brand Name Thetford
Type family N80-N90-N97-N100-N104-N109-N110-N112-N145-N150
Manufacturer’s (Factory)
Name Thetford B.V.
Address Nijverheidsweg 29
Telephone no INT+31-765042200
Telefax no INT+31-765042300
The following harmonised standards or technical specifications (designations) which comply with good engineering practice in safety matters
in force within the EEA have been practised.
EN 60335-1 (IEC 335-1), EN 60 335-2-24 (IEC 335-2-24) Low Voltage Directive
EN 61000-3-2, EN 61000-3-3, EN 55014-1, EN 55014-2 EMC Directive
EN 732, EN 50165 GAS Directive
The equipment conforms completely with the above stated harmonised standards or technical Specifications.
By signing this document, the undersigned declares as manufacturer, or the manufacturer’s authorised representative established within the
EEA, that the equipment in question complies with the requirements stated above.
Manufacturer
Date Signature Position
29-03-2005 Louis van Eil General Manager Engineering
1 2 3 4
9
5
6
7
8
10
A D C B
A C B
BA C D
Dimensions Gross volume incl. Net volume incl. Volume freezer Input * Input * Net weight Operation
Model H x B x D (mm) freezer Freezer (L) (kWh/24h) (gr./24h) (kg)
depth incl. door (L) (L)
N80 – N1F1x1P 821 x 486 x 543 81 75 10 2.5 238 22 Manual (piëzo)
N80 – N1F1x2E 821 x 486 x 543 81 75 10 2.5 238 22 Electric
N90 – N2F2x1P 821 x 525 x 547 91 84 11 2.8 238 26 Manual (piëzo)
N90 – N2F2x2E 821 x 525 x 547 91 84 11 2.8 238 26 Electric
N97 – N2F4x6E 821 x 525 x 582 97 90 11 2.8 238 24 Electric
N97 – N21F4x6A 821 x 525 x 582 97 90 11 2.8 238 24 Smart Energy Selection
N100 – N3G2x1P 821 x 525 x 543 97 91 11 3.3 340 30 Manual (piëzo)
N100 – N3G2x2E 821 x 525 x 543 97 91 11 3.3 340 30 Electric
N100 – N31G2A 821 x 525 x 543 97 91 11 3.3 340 29.5 Smart Energy Selection
N104 – N3G4x6E 821 x 525 x 578 104 98 11 3.3 340 27,5 Electric
N104 – N31G4x6A 821 x 525 x 578 104 98 11 3.3 340 27,5 Smart Energy Selection
N109 – N3F5x2E 821 x 525 x 543 103 95 11 3.3 340 26.5 Electric
N109 – N3F4x6E 821 x 525 x 543 103 95 11 3.3 340 26.5 Electric
N110 – N3G8x4P 821 x 525 x 603 103 95 11 3.0 340 30.5 Manual (piëzo)
N110 – N3G8x4E 821 x 525 x 603 103 95 11 3.0 340 30.5 Electric
N112 – N4F4x1P 821 x 525 x 632 113 107 11 3.1 340 26.5 Manual (piëzo)
N112 – N4F4x2E 821 x 525 x 632 113 107 11 3.1 340 26.5 Electric
N112 – N4F4x6E 821 x 525 x 632 113 107 11 3.1 340 26.5 Electric
N145 – N5H6x5x 1245 x 525 x 543 141 138 23 4.5 420 39 Electric/SES
N145 – N5H6x6E 1245 x 525 x 543 141 138 23 4.5 420 38 Electric
N145 – N5H6x6A 1245 x 525 x 543 141 138 23 4.5 420 38 Smart Energy Selection
N150 – N5H7x6E 1245 x 525 x 578 150 147 25 4.5 420 38.5 Electric
N150 – N5H7x6A 1245 x 525 x 578 150 147 25 4.5 420 38.5 Smart Energy Selection
* average energy consumption at ambient temperature of 25° C
TECHNICAL DATA
Thetford absorber refrigerators:
Category C11
AC 230V (50/60 Hz)
DC 12V
Gas types I3+ (G30: 28-30/G31: 37 mbar) (Countries: BE, FR, IE, LU, PT, ES, GB, GR, IT)
I3B/P (G30/G31: 28-30 mbar) (Countries: DK, DE, IS, NL, SE, FI, NO)
(G30 = butane, G31 = propane)
6071_C.qxd 28-06-2005 15:43 Pagina 2
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Thetford N110 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info