FIKO 70
_________________________________________________________________________________________
3
to the maximum position 1 (= open). Set the firing flap valve on 1 (= open). After firing the fireplace door must be shut. When the fire
burns well add one dose of wood or briquettes through the fireplace door. At that moment ash box door must be kept shut.
FIKO 70, FIKO 70 A, FIKO 70 Nostalgia
Firing flap valve is opened Firing flap valve is closed
FIKO 70 Nostalgia B, Fiko 70 Ratio, FIKO 70 Plus
Firing flap valve is closed Firing flap valve is opened
8. HEATING
In through of heating the oven´s door must to be opened!
Burning wood:
Nominal heating capacity can be obtained with 2-3 wood logs (about 2.2 kg). Ash box door must be kept shut. Use only primary air slider
to burn fuel down. Shut the rotary primary air slider on the ash box door after approximately 10 minutes.
Burning down rate depends on local conditions including the chimney draught and air supply sliders positions.
Burning lignite briquettes:
Nominal heating capacity can be obtained with 3 lignite briquettes (approx. 1.7 kg).
Use the rotary primary air slider on the ash box door to control the fire. Ash box door must be kept shut.