The outdoor combustion air could be supplied to the heater through the connecting socket which can be mounted on the bottom of the
backside of the heater.
10. Fire Protection
Distance from flammable structures and furniture
To assure adequate heat protection, a minimum distance of 20 cm in the back and 20 cm on the sides is required between the heater
and flammable structures and furniture.
Fire protection within radiation perimeter
Make sure that no flammable structures or furniture are within radiation perimeter of glass door, which is 80 cm. The distance may be
reduced to 40 cm if safety shade is installed between fireplace and flammable structures leaving enough space on both sides.
Fire protection outside radiation perimeter
Minimum distances from flammable structures and furniture are stated on heater’s label and must be observed.
Heater
For solid fuel heaters floor in front of fireplace’s door made of flammable materials must be protected by a non-flammable hearth. Its
minimum dimensions are 50 cm in the front and 30 cm on the sides of fireplace door.
11. Spare Parts
Only spare parts approved or provided by the manufacturer may be used. For inquiries, please, contact a specialized vendor.
No modifications to heater are allowed!
12. Warning in case of fire in chimney
Deposit in chimney may catch fire if unsuitable or humid fuel is used. In such case close all heater air holes immediately and call the fire
brigade. After fire is extinguished chimney should be inspected by an expert for cracks or untight places.
13. Nominal heating capacity, combustion air adjustment, and fuel burning time
Nominal heating capacity of heater is 11,5 kW for wood and 8,5 kW for lignite briquettes it is obtained at minimum supply
pressure of 12 Pa:
When operating with wood, the air regulator is set so that the regulator arm is set perpendicular to the front wall of the stove, that is,
the primary combustion air supply is completely closed and the secondary combustion air supply is completely open.
When operating with brown coal briquettes, set the air regulator so that the regulator arm is set to the right, meaning that
the primary and secondary air inlets are fully open.
The combustion air regulator arm is located under the front door. The handle can be manipulated with a handle that is a tile fitting.
Quantity and adjustment of combustion air for moderate operation:
14. Space Heating Capacity
For rooms with insulation non-conform with calorific insulation regulations space heating capacity should be determined pursuant to DIN
18 893 for nominal heating capacity of 11.5 /8.5 kW:
in favourable heating conditions - 220 m
3
in poor heating conditions - 180 m
3
in unfavourable heating conditions - 120 m
3
For occasional heating – interrupted for more than 8 hours – space heating capacity is reduced by 25%.
15. Technical Data
Capacity: 11.5 / 8.5 kW
Weight: BILBAO = 125 kg, BILBAO UNI = 130 kg, MALAGA = 125 kg, MALLORCA UNI = 135 kg
Upper flue gas outlet: 150 mm