29. Front-mounted Stereo input 2 jack [ST 2 IN]
–10dB*,10kΩ,unbalancedtype,stereominijack.
It is internally connected in parallel to the Stereo
input 2. Adjust the input level with the Stereo 2
Input volume fader (28).
30. ARC switch and ARC operation indicator
[ARC] (Green)
Press this switch to enable the Automatic
Resonance Control function (ARC).
Hold down this switch for 3 seconds to start
the ARC measurement, and the ARC operation
indicatorashes.
Uponmeasurementcompletion,theARClteris
set, and the ARC indicator lights. (See p. 28.)
31. Recording output switch and Recording
output indicator [REC OUT] (Green)
The indicator lights when the switch is pressed,
and the Control knob (6) is allowed to adjust the
recording output volume. (See p. 25.)
* 0 dB = 0.775 V
[Rear terminal section]
32 33 34 35 36 3637
38 38
39 39
40
41
42 43 44
32. AC inlet
Connect this inlet to the AC wall outlet using the
supplied dedicated power cord.
33. Output terminals [OUTPUT 1 – 4]
+4dB*,600Ω,balancedtype,removableterminal
block.
The input channel signals assigned to Buses
1 through 4 using the Assignment switches (19
and 26) are output from each individual output
terminal.
Buses 1 through 4 correspond to the output
terminals 1 through 4, respectively.
34. Contact output terminals [OUTPUT C, 1, 2, 3,
4, 5, 6, 7, 8, C]
Removable terminal block, 8-channel contact
output terminal.
Perform function assignment to each contact by a
PC using the supplied M-864D PC Software.
35. Contact input terminals [INPUT C, 1, 2, 3, 4, 5,
6, 7, 8, C]
Removable terminal block, 8-channel contact
input terminals.
Perform function assignment to each contact by a
PC using the supplied M-864D PC Software.
36. AC adapter input [LINK A and LINK B]
Connect the dedicated AC adapter or its
equivalent* that supplies 24 V DC power to the
ZM Remote controller.
* Use the AD-246 AC adapter (optional) or its
equivalent. As for the usable adapter, consult
your TOA dealer.
37. Termination switch [TERMINATION ON, OFF]
UsedtoturnONorOFFtheterminationof120Ω
for parallel connection.
38. Data line connection terminals [D+, D–]
Connect the data line from the ZM Remote
controller to these terminals.
Match the polarity.
39. 24 V DC output terminals [DC 24 V, + and –]
Supply 24 V DC to the ZM Remote controller.
40. LAN port
Connect this port to the LAN-connected switching
hub using a LAN cable.
The MX-864D’s default IP address is “192.168.14.1.
Perform settings by a PC using the supplied
M-864D PC Software.
• Link indicator
Lights when the link is established and during
data transmission or reception.
• Full indicator
Lights during Full duplex operation.
41. Functional ground terminal
Connect this terminal to the functional ground of
external equipment if much noise is encountered
when the digital audio processor is connected
to the external equipment. The noise may be
reduced
Note: This ground is not for protective ground.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Toa M-864D wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info