SE T UP
CL EA N YOU R STE RIL IS ER BEF OR E FIRS T US E - Refe r to pa rt s gu ide a nd di agr am
1. Do n ot co nne ct t o pow er at t his st ag e.
2. Rem ove al l ite ms f rom i nsi de th e ste ri lis er ba se.
3. Pou r exac tl y 80 ml of w ater i nto t he st eri lis er ba se.
4. A sse mb le th e low er tr ay (A) w ith l og o fro nt fa ci ng an d upp er tr ay (B) a nd pl ace i n th e ste ril ise r bas e.
5. Add t he l id.
6. Co nne ct t he le ad an d plu g int o the m ain s sup ply. Sw itc h on at m ain s sup ply.
7 . Pre ss t he pl ay sw itc h and i t wil l lig ht up a mbe r to sh ow th e ste ril isi ng ha s be gun.
8. Th e lig ht wi ll sw itc h of f whe n ste ri lis ing h as n ish ed.
9. Al low t o co ol fo r 5 mi nute s bef ore t ur nin g of f at th e mai ns, r emo vin g the p lu g and st er ili ser l id.
10. Rem ove up per t ray a nd lo wer t ray, pou r away a ny rem ain ing w ater a nd w ipe d ry. Your st eri lis er is n ow re ady t o use .
Th is st er il is er i s de sig ne d fo r us e wi th Tomm ee T ip pe e bo tt l es an d fe ed in g ac ce sso ri es (e xce pt b ot tl e br us h).
Th e st er ili se r wi ll ho ld a m ax im um of 6 Tom me e Ti pp ee b ot tl es o r a co mb in at io n of fe we r bo tt le s pl us
so oth er s an d br ea st p ump p ar t s.
PA RT S GU I D E
CLEAN ING
Unp lu g and a llo w to co ol b efo re cl ea nin g. Af te r eac h use p our a way re mai nin g wate r fr om th e ste ri lis er ba se by t ipp ing
th e ster il ise r sid eway s over a s ink a nd wi pe c lea n wit h a dam p cl oth o nly. Do n ot c lea n wit h abr as ive c lea ner s or al low
to c ome i nto c ont ac t wit h so lven ts or h ar sh ch emi ca ls, d ama ge c oul d re sult .
DE- SCALI NG
Th e fre que ncy o f de -s ca lin g sho uld b e as fo ll ows:
Har d wat er: 14 d ays
Me diu m: 21
Sof t : 28
You can nd ou t you r wate r qua lit y vi a you r wate r pro vid er. FAQs an d a pic tur e of li mes ca le c an be f oun d on o ur
web sit e. Af te r eac h use p our a way re mai nin g wate r fr om t he uni t bas e by ti ppi ng th e uni t si deway s over a s ink a nd
wip e wi th a da mp c lot h onl y. Unpl ug th e uni t and a llo w to c ool b efo re c lea nin g. A bu ild u p of lim es ca le c an ne gat ivel y
af fe ct th e pe rf or man ce o f the u nit . We re co mme nd c arr y ing o ut th e de sca lin g pr oc ess a s per a bove f re que ncy
gui de line s to e nsur e th e uni t con tin ues t o wor k ef cie ntl y. Livi ng in a h ard w ater a re a can p ro duc e lim es cal e qui cke r
th an oth er a rea s the ref ore d esc al ing i s req uir ed so on er. Use a d esc al er th at is s uit abl e for u se w ith s tai nle ss s tee l and
use a s per t he m anu fac tur er ’s gui del ine s. A lte rna tiv ely y ou c an us e whi te vi neg ar or a d esc al ing s ac het to d esc al e
you r uni t, pl eas e use a s per m anu fac tu rer ’s gu ide lin es. W her e no m eth od is s tat ed, 1 s ach et to 2 00 ml o f hot wa ter r ati o
ca n be ap pli ed. S ee o ur web sit e fo r det ail ed de sc ali ng me tho d. O nce y ou hav e des ca led t he n fol low i nst ru cti ons u nd er
set u p to pe r for m a n al cl ea nin g cyc le. D O NOT us e met al o bje ct s or sc ou rer s to c lea n your u nit . DO N OT use b le ach
or st er ili sin g ui d to c lea n the u nit . DO N OT use a bra siv e or ant i- ba cte ri al ma ter ial s. D O NOT sc ru b th e heat p lat e.
TROUBLESHOOT ING
Steriliser will not work
Che ck t he ma ins l ead i s plu gge d int o the u nit a nd t he ma ins s ocke t is sw itc he d on. Ch ec k the f us e is in t he pl ug (i n
a UK p lug o nly). C hec k th e soc ket by p lug gin g in an oth er ap pli anc e. Ch ec k the a ppl ian ce by p lu ggi ng int o ano the r
socket.
Excessive steam
Che ck t hat i tems a re c or rec tl y loa ded i n ste ri lis er. Use ex act ly 8 0m l.
Bo tt le s co me o ut w it h a ch alk y m ar k
Steriliser needs descaling. Refer to Cleaning Instructions.
Cy cle t ak es t oo lo ng t o co mp le te
Too muc h wate r in st eri lis er. Use ex act ly 8 0m l.
a. Rem ovab le l ower t ray
b. Rem ovab le up pe r tray
c. Dr y ing r ack ( par t s a+b) wit h ste ri le su r fac e
d. Loc at or fo r tom mee t ip pee b ot tle n ec k
e. Loc at or fo r tom mee t ip pee a nti - co lic v alve (f or
use i f ste ri lis ing a dvan ce d ant i- c oli c bot tl e)
f. Loc at or fo r bot tl e ho od
g. Li d
h. Steriliser base
i. Lea d wit h pl ug
j. Powe r but to n (pl ay)
k. Stop button
l. Sterilising indicator light
m. S team v ent s
n. 80ml mea surement on T ommee Tippee bottle
o. Cable tidy
m
g
f
b
e
d
a
i
l
j
k
h
o
c
n
IN FOR MATI ON O N TH E DI SP OSA L FOR WA STE E LEC TR ICA L & EL ECT RON IC E QU IP ME NT ( WE EE)
This symbol on the products a nd accompanying documen ts means that used electrical and electronic products
should not be mix ed with general household waste . For proper dis posal for trea tment, recov ery and recycling , please
ta ke the se p rod uct s to d esi gna ted c ol lec ti on po int s wh ere t hey w ill b e acc ep ted o n a fre e of c har ge ba sis . In so me
co unt ri es yo u may be a ble t o ret ur n your p ro duc ts to y our l oc al re tai le r upo n the p urc ha se of a n ew pr odu ct.
Di spo sin g of th is pr od uct c or re ct ly wi ll he lp yo u save va lua ble r es our ce s and p reve nt any p oss ib le ef fe ct s on hu man
hea lt h and t he env ir onm ent , whi ch c oul d oth er wi se a ris e fr om in app rop ri ate w aste h and lin g. Pl eas e co nta ct yo ur lo ca l
aut hor it y fo r fu rt he r det ail s of you r nea re st co lle ct io n poi nt fo r WEE E.
Penalties may be applicable for the incorrect disposal of this product in accordance with national legislation.
Th e pro duc t is tte d wi th a BS 13 63 m ain s plu g co nta ini ng a fu se. I f it eve r bec om es ne ce ss ar y to re pl ace t he f use ,
onl y use f us es th at ar e mar ked B S 136 2, and r ate d at 5A . I n the u nli kely ev ent t hat t his p lug i s not s uit abl e fo r the
so cket s in yo ur ho me, i t sho uld b e rem ove d and a s uit abl e plu g t te d as fo llo ws:
Th e wir es of t he ma ins l ead a re c olo ure d in ac c ord anc e wi th t he fo llo win g co de:
GR EEN A ND Y EL LOW – E ART H
BLU E – NEU TR A L
BRO WN – LI VE
As t hes e co lo urs m ay not c or re spo nd w ith t he c ol our ed ma rk ing s som eti me s use d to id ent if y th e
terminals in the plug, connect as follows.
Th e wir e co lou red G RE EN A ND Y ELLOW m ust b e co nne ct ed to t he te rm ina l mar ked E o r by th e
ear t h sym bol o r co lo ure d GR EEN o r GR EEN A ND Y ELLO W. The w ire c ol our ed B LUE m ust be
co nne cte d to t he te rm inal m ar ked N o r co lou red B L ACK . Th e wir e co lo ure d BRO WN m ust b e
co nne cte d to t he te rm inal m ar ked L o r co lou red R ED.
If yo u are i n any do ubt a bou t how t o wir e a pl ug or r epl ac e a fus e saf ely, c ons ult a qu ali e d
electrician.
USAG E
Bef or e ster il isa tio n, wa sh al l bot tl es an d fee din g ac ce sso ri es in w ar m soa py wate r or i n a dish was her (t op ra ck on ly) to
remove a ny milk residues. Sepa rate all components for wa shing and reassemble teat and screw ring for sterilising.
WARNINGS
MO RE T HA N 80 M L OF WATER I N TH E STE RI LIS ER BA SE WI LL P ROLO NG T HE CYC LE TI ME . LES S TH AN
80 M L MAY NOT ST ERI LIS E IT EMS P RO PER L Y . DUR ING S TER ILI SATIO N HOT S TE AM PAS SE S THR OU GH T HE
VE NTS AT TH E TOP O F TH E UN IT. POSI TIO N TH IS U NIT AWAY FRO M WAL LS A ND M AK E SU RE I T IS N OT
UN DE RN EATH A NY OV ER HA NG IN G SH ELVES OR C AB IN ETS . DO N OT OPE N TH E STE RIL IS ER UN TI L THE
LIG HT H AS SW ITC HED O FF , OR YOU H AVE PR ESS ED T HE STO P BU T TON A ND WA IT ED 5 MI NU TES TO A LLOW
FOR COOLING.
1. Pla ce o n a at , hea t res ist ant
wor k su rf ac e. Pou r exac tl y 80 ml
of wat er in to th e ste ri lis er bas e.
Y our T ommee Tippee bottles
have a h and y 80 ml m eas ure.
4. Pla ce t he up per t ray o nto
th e lowe r tr ay.
7 . Pla ce t he li d ont o the s ter ili se r
bas e and p lug t he l ead i nto t he
mains power .
10. The s top b ut ton i s the re in c as e
you n eed t o man ual ly st op yo ur
ste ri lis er mi d cyc le. I f you d o thi s you
wil l have t o res ta rt t he s ter ili sin g
pr oce ss f ro m the b egi nni ng as t he
contents will not be sterilised.
13. Wash y our h and s tho rou gh ly
before handling sterilised items .
Take car e as th e ite ms ma y be
hot . Rem ove t he ste ri lis ed
ite ms. T he te at to ngs c an b e
use d to r emov e the s mal l ite ms.
2. As sem bl e lowe r tr ay into t he
ste ri lis er ba se wi th lo go f aci ng
for w ard s on t he ri ght h and s ide .
5. Pla ce t he as sem bl ed te at an d
sc rew r ing o nto t he up per t ray. It
is im po rt ant n ot to h ave th e
ho ods tt ed on to th e tea t and
screw ring.
8. Pre ss t he pl ay but to n to st ar t
th e mac hin e. An a mbe r lig ht wi ll
co me on . Thi s sh ows t hat t he
ste ri lis er is i n its w arm u p pha se
and w il l auto mat ic all y beg in t he
sterilising phase when the
appropriate temperature is
reached.
1 1. A f ter t he cy cle h as n ish ed
all ow to c oo l fo r at le ast 5
minutes before opening the
steriliser . We recommend that
you h ol d the l id by t he t wo si de
han dle s, li f t ver ti ca lly u nti l you
have c le are d the u pp er tr ay th en
ti lt th e lid t o an an gle a way fr om
you t o all ow th e wat er to dr ain .
14. The t ray s ca n be us ed se par ate ly
as a dr y ing r ack o r ste ri le su r fac e.
9. Th e lig ht wi ll aut oma tic al ly sw itc h
of f wh en th e ste ri lis ing p has e
has nished.
12. The c on tent s wi ll re mai n ste ril e
for 2 4 hou rs if t he s ter ili ser
is unopened.
15. T o hel p in th e re duc ti on of
lim esc al e, en sur e tha t the u nit i s
dr aine d an d wip ed af te r use o nc e
fully cooled.
3. Pla ce t he bo tt le s nec k dow nwa rds
int o the l oc ato rs of t he r emov abl e
tr ay. This i nc lud es lo ca tor s for
advanced anti-c olic valves.
6. Sl ot th e hoo ds in to th e ho od
lo cat or s of th e rem ovab le up per
tr ay so th at th ey ha ng ove r the
tea t and s cre w ri ng bu t are n ot
fully assembled.
1
4 5 6
9 8 7
10 11 12
151413
2 3