• Operating Instructions
These Operating Instructions describe how to use
the prodct properly and safely. The safety advice and
information as well as the accident prevention and
general safety regulations for the field of application
must be complied with.
(factory-set operating mode)
(factory-set operating mode)
The sliding gate operator can be actuated by an
impulse generator, such as hand transmitter, key
switch etc. It is only necessary to generate a short,
sharp impulse.
In same operating mode as for single-lane control,
however, receiver remains plugged into operator.
Operator starts up and gate travels to open position.
No effect, gate continues to open.
Gate closes.
Gate stops and then reopens.
Red-green traffic light control is only possible
together with the additional A800 traffic light control
system. Generating an impulse always causes the
gate to open. After the green and clearance phase
has elapsed, gate automatically closes. If a new
opening impulse is generated during the green
phase, this is extended.
you may only drive through the gateway
during the green phase.
All persons using the gate system
must be shown how to operate it
properly and safely.
Keep hand transmitters out of the reach
of children.
When the operator is being used, the
opening and closing phases must be
monitored. It must be ensured that
neither persons nor objects are located
within the gate’s range of travel.
Normal operation (0)
Normal operation (0)
OPEN-CLOSE operation (1)
Functional sequence:
Operation with single-lane control (1)
Caution:
Operating modes
Functional sequence:
Partial opening
IThe respective setting for menu 9 is shown in
brackets.
Operator starts up and causes gate to travel to set
open or closed travel limits.
Gate stops.
Gate continues to move but in opposite direction.
Partial opening of approx. 1 m instead of full opening
can be triggered by the hand tranmsitter or another
command generator.
First impulse:
IImpulse generated whilst gate is moving:
A new impulse:
Impulse generation in the closed position:
IImpulse generation whilst gate is opening:
Impulse generation in the open position:
Impulse generated whilst gate closes:
Automatic closing (2)
Automatic closing (3)
Automatic closing (4)
Functions of the safety devices
IInternal force limit device
Signal light
Disengaging the operator
Empty batteries must be disposed of separately
(toxic waste)!
Generating an impulse always causes the gate to
open.
IIf a photocell is installed, an interruption during the
closing phase causes the gate to stop and then travel
in the opposite direction. An interruption while the
gate is opening has no effect.
If a signal light to signal the opening and closing
phases is installed, this starts to flash as soon as a
start impulse is given. The operator starts up in
accordance with the set advance warning phase.
During the flashing phase, driving through the
gateway is not permitted.
When making adjustments and in the event of power
failures or malfunctions, the operator can be
disengaged and the gate be moved by hand. Open
and remove the cover with the triangular wrench.
Pull the pull cord with knob, 8 is displayed. The gate
can now be opened and closed by hand.
To resume power-operation, actuate the lever and
the operator re-engages. Replace the cover and lock
in place with the triangular wrench.
Programming further hand transmitters:
See menu stages 1 and 2 (figures 21 and 22).
Changing the battery: Slide back the battery
compartment cover on the hand transmitter.
Take out the battery.
Insert a new battery (alkaline 23A, 12V). Be sure to
pole correctly! Slide the cover back on.
After the hold-open phase and the advance warning
phase have elapsed, the gate automatically closes.
Generating an impulse always causes the gate to
open.
After the hold-open phase and the advance warning
phase have elapsed, the gate automatically closes.
If the photocell is interrupted, the hold-open phase is
prematurely terminated and the advance warning
phase commences.
Generating an impulse always causes the gate to
open.
After the hold-open phase and the advance warning
phase have elapsed, the gate automatically closes.
If an impulse is generated, the hold-open phase is
prematurely terminated and the advance warning
phase commences.
If the closing gate encounters an obstruction, the
operator stops and causes the gate to open to clear
the obstruction.
During the soft run of the closing phase, the gate is
opened a slight gap only, just sufficient to clear the
obstruction.
If during the opening phase the gate encounters an
obstruction, the operator stops and causes the gate
to reverse for approx. 1 sec.
Photocell
Hand transmitter
17
Maintenance / Checks
The gate system must be inspected and
tested by a specialist company prior to
initial operation and at least once a year
thereafter.
Monitoring the force limit
Caution!
The operator control unit features a dual-processor
safety system to monitor the force limit.
The integral force cut-out is automatically tested at
each travel limit.
The gate system must be checked prior to initial
operation and at least once a year thereafter, In the
process, the force limiting device (figure 20) must be
tested!
If the closing force is set too high,
persons can be placed at risk of injury or
property could sustain damage.
GB
Retain these installation, operating and maintenance instructions for the full duration of the operator’s service life!
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Tormatic NovoGate wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info