497513
20
Zoom out
Zoom in
Vorherige Seite
1/21
Nächste Seite
19
EN
Selecting the remote controller functions
Change the settings of the remote controller functions
as required by taking the steps below.
How to change the remote controller functions
1 While operation is shut down, push the button
(43) and button (48) together for at least 4
seconds.
The numeric displays and display blink,
and the fixed louvers display lights.
2 Push the TEMP and buttons (49).
Repeatedly push the buttons until the setting to be
changed blinks on the display.
3 Push the TIME and buttons (40).
Repeatedly push the buttons until the setting to be
changed blinks on the display.
4 Push the button (42). Then push the button
(43) to return to the original screen.
When the button (42) is pushed, the numeric
displays and display stop blinking and
light up, and when the button (43) is pushed
again, they go off.
Items to be set
24-hour/12-hour display setting <code No.10>
The 24-hour display or 12-hour (AM/PM) display
can be selected for the clock which is displayed on
the remote controller.
This item’s selection is also reflected on the clock
displayed on the clock setting screen and program
input screen.
Restriction on button operations <code No.12>
This item sets the range of the restriction placed on
the button operations which can be applied while
scheduled operations are being performed.
Setting: 0000 (factory setting)
Code No.12
O: Can be operated.
X: Cannot be operated.
Display/non-display of clock <code no.13>
This item selects and sets whether the day of the week
and clock time are to be displayed.
Setting: 0000 (factory setting)
Code No.13
O: Display X: No display
Selection of operation when power is restored after a
power outage <code No.14>
This item selects the operation to be performed when
power is restored after a power outage occurred
during a scheduled operation.
0000: No operations are performed when the power is
restored, and the scheduled operation is resumed as
soon as the program time is reached after the power
has been restored. (When the power is restored, the
scheduled operation is based on the operation of the
indoor units.)
0001: If there was a programmed operation during the
power outage, that operation is performed when the
program is resumed. If there is no programmed
operation or if the “Continue xx” setting is in place, the
operation prior to the power outage is resumed.
Selecting the functions using the DIP
switches of the remote controller
The following functions can be selected using the DIP
switches on the remote controller’s circuit board.
Setting procedure
Open the back cover of the remote controller, and
select the functions using the DIP switches located at
the bottom left of the circuit board.
After establishing the settings, turn the ground fault
interrupter off and then back on.
Setting items
Remote controller header/follower setting: Bit 1
When operating the air conditioner using two remote
controllers, set one of the controls to be the follower.
* Set the remote controller used as the schedule timer
to be the header.
Operation function setting: Bit 2
One of the following three operation functions can be
selected and set.
1.Scheduled operation function
2.Timer operation function
3.No scheduled or timer operation function
Setting Description
0000:
0001:
24-hour display (factory setting)
12-hour (AM/PM) display
Setting [ON/OFF] [MODE] [TEMP.]
0000 O O O
0001 X O X
0002 X X X
0003 O X X
0004 O X O
Setting
Scheduled operation
underway
Scheduled operation
in standby
Air
conditioner
now
operating
Air
conditioner
now shut
down
Air
conditioner
now
operating
Air
conditioner
now shut
down
0000 O O O O
0001 X X X X
0002 O O X X
0003 O X X X
0004 O O O X
0005 O X O X
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

toshiba-rbc-ams41e-remote-control

Suche zurücksetzen

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Toshiba RBC-AMS41E Remote control wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info