2. Activate Weekly Timer Operation
During operation (in a SW/ON position), press the “AUTO” button to enter the weekly timer operation mode. The
“AUTO” sign will be shown on the display. However, if no program is set, you can hear the beep sound and
cannot enter the weekly timer operation mode. Press the “▲MIN.” button or the “▼HOUR” button to change the
set temperature. However, if the next program starts, the temperature will be changed to the temperature of the
next program.
During operation, press the “TIMER” button to enter the weekly timer set mode (Select of the program number). If
the “TIMER” button is pressed during the setting of the weekly timer set mode, the weekly timer set mode is
released. Change of setting is applied as soon as the AUTO operation starts.
MANUAL COMBUSTION
IMPORTANT: This feature is for testing purpose only!
This heater also can be kept burning at desired combustion mode (High, Medium or low) manually, regardless of
room temperature.
1. Press the “▲MIN.” button and “▼HOUR” button at the same time for more than three (3) seconds when ON /
OFF switch is “ON”.
2. P1, P2 or P3 will be displayed on the Digital indicator;
P1 = Low mode
P2 = Medium mode
P3 = High mode
Then select desired combustion mode by pressing “▲MIN.” or “▼HOUR” button. “▲MIN.” button changes
combustion mode to higher, “▼HOUR” button changes combustion mode to lower.
3. To clear, press the “▲MIN.” button and “▼HOUR” button at the same time for more than (3) seconds until
normal temperature display returns.
AUTOMATIC CLEANING MODE
When the heater has been burning continuously for two hours at its highest setting, the burner will automatically
start an auto clean procedure. The display will show the auto cleaning code cl:05 running back to cl:01. The
procedure takes 5 minutes to clean the burner automatically while the heater will burn at its lowest setting. When
the burner is clean again, the heater will automatically switch back to the highest setting again.