The fan of indoor unit will not start running immediately after the heating is started to avoid blowing out cold air.
When it is cold and wet outside, the outdoor unit will develop frost over the heat exchanger which will decrease the
heating capacity. Then the air conditioner will start defrost function.
During defrost, the air conditioner will stop heating for about 5-12 minutes.
Vapor may come out from the outdoor unit during defrost. This is not a malfunction, but a result of fast defrost.
Heating will resume after defrost is complete.
NOTES FOR TURNING OFF THE AIR CONDITIONER
When the air conditioner is turned off, the main controller will automatically decide whether to stop immediately or
after running for several seconds with lower frequency and lower air speed.
EMERGENCY OPERATION
If the remote controller is broken or lost, use emergency switch button to operate
the air conditioner.
If this button is pushed when unit is OFF, the air conditioner will operate in AUTO
mode.
If this button is pushed when unit is ON, the air conditioner will stop running.
ADJUSTMENT OF AIR FLOW DIRECTION
Use U/D SWING up-down swing and L/R SWING left-right swing buttons on the
remote controller to adjust the air flow direction.
For the models without L/R SWING left-right swing function, the fins has to be
moved manually.
Note: Move the fins while the air conditioner is not in operation, or your fingers might be
insured, and unit can also be damaged.
Never place your hands into the air inlet or outlet when the air conditioner is in operation.
PAY ATTENTION
Open front panel of indoor unit.
The connector must not touch the terminal board, and is positioned as shown in Fig.
CLEAN AND MAINTENANCE
CLEANING THE INDOOR UNIT
1. Turn off the unit and cut off the power supply. Wait after that at least 5 minutes before you start cleaning of the unit
otherwise there might be the risk of electric shock.
2. Clean the indoor unit (only the outside plastic parts) with dry or damp soft cloth in cold water. Do not spray or spill the
unit in order to clean it.
3. Clean air filters regularly, in order to avoid accumulation of dust that might affect the good performance of the air
conditioner. After removing the air filters, do not touch the metallic parts. It might cause injury.
4. Do not use water which temperature that exceeds 40oC to clean the front panel. Otherwise it may cause deformation
or discoloration.
5. Do not use liquids, hard detergents, thinner, gasoline or any other chemical product for cleaning. Otherwise plastic
parts of the air conditioner might be damaged or even cause electric shock.
CLEANING THE AIR FILTERS
Remove pre-filters and heathy filters
Use both hands to open the front panel for an angle from both ends of the panel in accordance with the direction of
the arrow, until it clamps in a certain position. Lift gently the pre-filters until they unclench, release them from the slot
and remove them.
Refrigerant leakage contributes to climate change. Refrigerant with lower
global warming potential (GWP) would contribute less to global warming than
a refrigerant with higher GWP if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to [675]. This means that if 1 kg
of this refrigerant fluid would be leaked to the atmosphere the impact on global
warming would be [675] times higher than 1 kg of CO2 over a period of 100
years. Never try to interfere with the refrigerant circuit yourself or disassemble
the product yourself. These tasks should be carried only by licensed
authorized technician.
Ensure no following objects are under the indoor unit:
Microwaves, ovens and other hot objects.
Computers and other high electrostatic appliances.
Sockets that plug frequently.
The joints between indoor and outdoor unit shall not be reused, unless after re-flaring the
pipe.
The specifications of the fuse are printed on the circuit board, such as: 3.15A/250V AC, etc.
If your air conditioner is not fitted with a supply cord and a plug, an anti-explosion all-pole
switch must be installed in the fixed wiring and the distance between contacts should be no
less than 2.5 mm.
If your air conditioner is permanently connected to the fixed wiring, an anti-explosion
residual current device (RCD) having rated residual operating current not exceeding 30 mA
should be installed in the fixed wiring.
Power supply circuit should have leakage protector and air switch of which the capacity
should be more than 1.5 times of the maximum current.
USEFUL TIPS
Conditions where the Air Conditioner might not run normally
Cooling
Outdoor
>43oC (Apply to T1)
>52oC (Apply to T3)
Indoor
<18oC
Heating
Outdoor
>24oC
<-7oC
Indoor
>27oC
When temperature is too high, the air conditioner may activate the automatic protection device, so that the air
conditioner could be shut down.
When temperature is too low, heat exchanger of the air conditioner may freeze, leading to water dripping or another
malfunction.
In long-term cooling or dehumidification with a relative humidity of above 80% (doors and windows open), there might
be water condenses or dripping near the air outlet.
T1 and T3 refer to ISO 5151.
NOTES FOR HEATING
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Toyotomi Satori STN-STG-918R32 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info