14
Q&A
Q1.
What is the maximum cable length between the EAP110 and
the provided PoE adapter?
100 meters. The quality of the Ethernet cable may influence the
reception of the power supply.
Q2.
Could the EAP work as a standalone device if it had been
adopted by the EAP Controller?
No. By default, the EAP works as a standalone device. It will function
as a Managed AP once adopted by the EAP Controller. You can
Forget
this AP on the Controller management interface to turn it back as a
standalone device.
Q3.
Can I manage the EAP devices on a host without the EAP
Controller server?
Yes. Keep the EAP Controller software running on the Controller Host,
sign in to the EAP Controller using https://x.x.x.x:8043/login in
which x.x.x.x is the IP address of the Controller Host and 8043 is the
default port number for the server.
For example, the IP address of Controller Host is 192.168.0.100, you
can enter https://192.168.0.100:8043/login on other hosts in the
same LAN to reach the login page of the EAP Controller.