4) If the Auger Drive Motor is not operating but the Draft Inducer Fan is operating, the
problem is in the Auger system, which will need to be checked.
a) With the Power Switch and the Switch/Dial OFF, locate the small fan blade
on the back of the Auger Drive Motor.
b) While watching the fan blade, turn the Power Switch and then the Switch/Dial to
ON. If the fan blade does not turn, turn the Switch/Dial to OFF. This indicates a
defective Auger Drive Motor and it will need to be replaced. Contact your
Traeger Dealer or the Traeger Parts Department (SECTION SEVEN) to place
an order.
c) If the fan blade turns a bit and then stops, continue watching and turn the
Switch/Dial to OFF. If the fan blade UNWINDS slightly, this indicates a jam in
the Auger system which will need to be cleared.
d) Disconnect Power Cord from electrical outlet and remove Pellets from the Pellet
Hopper. Check for foreign objects and wet/decomposed Pellets, both of which
can cause a jam in the Auger system. The Auger will need to be removed to
clear a jam in the Auger system. See “HOW DO I REMOVE THE AUGER IF IT
JAMS?” section below.
`
HOW DO I REMOVE THE AUGER IF IT JAMS?
1) Remove any covers necessary to access the Auger Drive Motor.
2) Remove the screw connecting the Auger Drive Motor shaft to the Auger shaft and
the screw retaining the Auger Bushing into the Auger Tube.
3) With a small pipe wrench or locking pliers on the Auger shaft, turn the Auger counter
clockwise. It will turn hard until it breaks free, then the Auger will turn freely.
4) Remove the Auger and clean all Pellets, ash or foreign objects from the Auger,
Auger Tube and Firepot. A shop-vac is ideal for this task.
5) Sand the outside surfaces of the auger with medium grit sandpaper. Check the
inside of the Auger Tube and sand it if needed. Vacuum the sanding grit out of the
Auger Tube and Firepot when finished.
6) Reinstall the Auger Bushing and the Auger into the Auger Tube, making sure that
the Auger rotates freely.
7) Re-attach the Auger shaft to the Auger Drive Motor shaft.
WHY DOES MY GRILL FIRE GO OUT ON “SMOKE” SETTING?
Excess ash in the Firepot may be the problem.
1) Open the Door/Lid and remove the Porcelain Grill, Grease Drain Pan and Heat
Baffle from inside the Grill.
2) IMPORTANT: Remove all unburned Pellets and ash from inside and around
the Firepot. A shop-vac is ideal for this task CAUTION! ASSURE THAT THE
GRILL IS COLD TO AVOID A FIRE FROM HOT ASH.
3) Replace the Heat Baffle, Grease Drain Pan and the Porcelain Grill and initiate start-
up procedure.
4) If this didn’t remedy the problem, contact Traeger Technical Support (SECTION
SEVEN) for additional troubleshooting help.
WITH THE TRAEGER DIGITAL CONTROL, WHAT DIAL SETTING IS
RECOMMENDED FOR STARTING THE GRILL?
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Traeger Select Pro - BBQ400.03 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info