WATER DRAINAGE
Manual(Figure 12)
Once the unit shuts down upon full water, turn off the unit and unplug
the power plug.
Put a tray for the water below the water outlet at the back of the unit.
Screw off the drain cap, unplug the water plug and water will flow out.
Tilt the unit slightly backward when draining.
If the water tray is full before the unit is empty block the water outlet
with the water plug as soon as possible to prevent the water from
flowing onto the ground or carpet.
Once the water is fully drained, insert the water plug and screw on the
water cap tightly.
Turn on the unit only after the water plug and drain cap are installed properly;
otherwise, the condensate of the unit will flow onto the ground or carpet.
Continuous drain (Figure 13 + 14)
1. Screw off the water cap insert a 13mm PVC drain hose 8mm-10mm into
the water outlet.
2. Connect the drain hose to the toilet or outdoor.
3. When operating in the heating mode, adopt continuous drain; other-
wise, the unit may shut down due to full water.
4. Put the drain hose in an inaccessible place at a height not above the
water outlet and keep the drain hose free from flexure.
Maintenance and Servicing
Prior to maintenance and servicing of the unit, turn off the power and
unplug the plug.
Clean the surface of the unit with wet soft cloth. Do not use chemical
solvents such as alcohol and gasoline; otherwise, the surface of the air-
conditioner may be damaged.
Clean the filters once every two weeks. If the filter frame and filter are
clogged with dust, the function of the air-conditioner may decrease
Take out the filter frame gently in the direction shown by the arrow (as
shown in Figure 15 + 16).
Put the filters into warm water (about 40°C) to which neutral cleaner is
added for cleaning and then dry them in the shade.
Make sure the filters are completely dry before placing them back in the
unit.
TROUBLESHOOTING
Problem/fault
indication
Cause Remedy
The air-conditioner
does not work
No power
Full water indicator
illuminates?
Ambient temperature too
low ?
The room temperature is lower
than the set temperature in the
cooling mode.
Connect the unit to a live
socket and turn it on.
Drain the water stored in the
unit.
It is recommended that this
unit be operated at 10-35°C.
Change the set temperature
Bad cooling or heating
effects
There is direct sunlight
The doors and windows are
open, the room is crowded or
there are other heat sources
in the cooling mode
Filter mesh very dirty
Air inlet or air outlet clogged
Draw the curtain on.
Close the door and window
and add new air-conditioners
Clean or replace the filter
mesh
Remove the obstruction
Large noise Air-conditioner not put on a
flat surface
Put the air-conditioner in a flat
and firm place (may reduce
noise)
The compressor does
not work
Initiation of overheat
protection.
Wait 3 minutes until the
temperature decreases and
then turn on the unit
The remote control
does not work
Too long a distance
The remote control does not
point toward the receiving
head of the remote control
The batteries have no
electricity
Bring the remote control
close to the air-conditioner
and ensure that the remote
control points toward the
receiving head of the remote
control.
Replace the batteries
Display E1 Pipe temperature sensor
failure
Check the pipe temperature
sensor and related circuits
Display E2 Room temperature sensor
failure
Check the room temperature
sensor and related circuits
Display E4 Anti-freeze protection Restore the functions
automatically once defrozen.
Full water indicator
illuminates
The water in the baseplate
of the unit reaches the full
water level
Drain the water in the
baseplate.
Instruction manual
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

tristar-ac-5517

Suche zurücksetzen

  • Ich habe für dieses gerät keine anleitung.können sie mir da weiterhelfen? Eingereicht am 31-5-2017 21:09

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Tristar AC-5517 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info