IMPORTANT
Before you charge your batteries please read through these instructions carefully. Warning - do not overcharge. Ni-Cd rechargeable
batteries can be recharged up to 1000 times. Please dispose of your defective or exhausted batteries in an environmentally friendly way.
WARNING: Disconnect the battery charger from the mains before inserting or removing the batteries. If the mains lead is damaged,
for safety reasons it must be replaced by the manufacturer, a service centre or an appropriately qualified person. Do not attempt
to charge non-rechargeable batteries. For use inside only.
From 1 to 4 batteries type AAA, AA, C, D and 1 or 2 9-Volt batteries can be charged.
CHARGING TIMES
Battery Type Ni-Cd Ni-MH Ni-Cd discharge time
AAA /UM4 0180 mAh/ 02 - 05 hrs 0550 mAh/ 06 - 10 hrs The discharge time
AA /UM3 0500 mAh/ 05 - 08 hrs 1200 mAh/ 10 - 20 hrs depends upon
C /UM2 1200 mAh/ 10 - 20 hrs 1800 mAh/ 15 - 25 hrs the capacity
D /UM1 1200 mAh/ 12 - 25 hrs 2000 mAh/ 20 - 30 hrs and battery charge state.
9 Volt 0100 mAh/ 05 - 10 hrs 0140 mAh/ 08 - 15 hrs
CHARGER OPERATION
The charger will charge Ni-Cd and Ni-MH rechargeable batteries.
Note: The charging process is indicated only by the red indicator light above the appropriate charging compartment.
The indicator
ባ just shows the condition of the batteries during »TEST«, as described in the next section.
a) When you insert the batteries please make sure that the polarity (+/-) is correct and the contact is good.
b) Push the plug into the mains socket (Set the control knob ቢ to "CHARGE").
c) The red LED lights up as soon as the charging process begins.
d) Do not overcharge rechargeable batteries - take note of the above charging times.
TESTING RECHARGEABLE BATTERIES
The batteries can be tested in the first slot ቤ (near the switch) only.
1) Set the control knob ቢ to "TEST". The red LED goes out.
2) Place the battery to be tested into the first slot.
3) The charge state indicator ባ shows the residual capacity/battery strength:
– Deflection to the right ("GOOD"): the battery has adequate residual capacity
– Deflection to the left ("DEAD"): the battery is uncharged/no longer useable. Recharge/dispose.
4) Note: battery testing does not interrupt charging of the other slots.
DISCHARGING RECHARGEABLE BATTERIES
• Set the control knob ቢ to "DISCHARGE".
When you insert the batteries please make sure that the polarity (+/-) is correct and the contact is good.
• All the red LED lights go out to show that discharging has started.
Note that the charger does not automatically start charging again on completion of the discharging process.
!