8 EN
humidifier B 3 E / B 4 E
Operation
Avoid open doors and windows.
Make sure that there are no moisture-sensitive objects
located in the immediate vicinity of the mist nozzle, since
water may condense near the mist nozzle.
Operating elements
26
24
18
20
22
27
19
21
25
23
No. Designation Meaning
18 Timer LEDs Indicates the selected number of
hours (2-12h in combination from
the symbols 2h, 4h, 6h. The sum of
the symbols indicates the desired
number of hours.)
19 UV lamp LED Is illuminated when the UV lamp is
activated
20 Low water level
LED
Flashes permanently when water
tank is low
Flashes 3times in succession when
the dry run protection is activated
21 On/off LED Illuminated when the device is
switched on
22 Timer button Switching the timer function on or off
23 UV lamp button For switching the UV lamp on or off
24 On/off button For switching the device on or off
25 Water level
indicator button
For switching the water level
indication lamp on or off
26 Nebulizer intensity
button
Select nebulizer intensity
27 Nebulizer intensity
LEDs
Indicate the nebulizer intensity
selected (level 1, 2 or 3)
Switching the device on
Info
If no operational input is made for40s, the control
panel(6) switches off.
1. Make sure that the water tank(4) has been filled with
drinking water.
2. Make sure that the device is neither damp nor wet on the
outside. Otherwise wipe it dry.
3. Press the On/off button(24).
ðThe nebulizer intensity LED(27) indicates the nebulizer
intensity at level1 an .
ðThe device starts to humidify. Fine water mist leaves the
mist nozzle(2).
Setting the nebulizer intensity
The nebulizer intensity can be set to 3levels:
Stage1: Low nebulizer intensity
Stage2: Medium nebulizer intensity
Stage3: High nebulizer intensity
üThe device is switched on.
1. Press the Nebulizer intensity button(26).
ðLED "1” of the nebulizer intensity LEDs(27), is
illuminated for the first level.
2. Repeat the process for stage2 or3.
ðThe device now operates with the desired nebulizer
intensity.
Setting the operating mode
You can select the following operating mode:
Manual humidification
Manual humidification
The nebulizer intensity can be set to level1–3 in this operating
mode at any time(continuous humidification regardless of the
humidity level in the room).
Timer function
For the device to switch off automatically after a predefined
number of hours (2 to 12h) you can program the timer. The
timer can be programmed in increments of 2hours.
Automatic switch-off
1. Press the timer button(22) once to program the timer to
2hours.
ðLED “2”of the timer LEDs(18) is illuminated.
ðThe device switches off automatically after 2hours.
2. Press the timer button(22) again to program the timer to
up to 12hours.
ðThe desired number of hours lights up as a combination
of the three LEDs.
Notes regarding automatic switch-off:
Pressing the On/off button(24) deactivates the automatic
switch-off function.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec B4E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info