external condensate pump External condensate pump DS/DH series
Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
Disconnect the power cable from the mains socket when
the device is not in use.
When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.
Never insert any objects or limbs into the device.
Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.
Intended use
Only use the device as a condensate pump in combination with
dehumidifiers. The device was designed for continuous
operation and is suited for the following pumping media:
clear water
slightly chlorinated or salted water
Improper use
Do not place the device on wet or flooded ground.
The device is not suitable for pumping potable water.
The device is not suitable for increasing the pressure of
existing water supply networks.
The device must not be used for aggressive, abrasive,
caustic, combustible or explosive pumping media.
Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
be aware of the dangers that occur when working with
electric devices in damp areas.
have read and understood the instructions, especially the
Safety chapter.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands
of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Behaviour in the event of an emergency
1. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
2. Do not reconnect a defective device to the mains.
Information about the device
Device description
When combined with a dehumidifier, the external condensate
pump can be used for failure-free continuous operation. With its
robust and corrosion-resistant housing it is particularly suited for
combination with the pool dehumidifiers of Trotec's DS and
DHseries, but can also be used with other dehumidifiers without
a hitch.
The fully automatic condensate pump can be installed quickly and
without difficulty and is specifically designed for pumping off
condensation water. It is particularly suited for applications with
long water discharge distances or for a longer permanent drying
of unattended rooms.
The power for the dehumidifier should be supplied via the
condensate pump. To do so, either use the socket of the
condensate pump(6), or directly wire the dehumidifier to the
pump via the connector for direct supply(5). For direct supply, the
internal plug connections and a female connector are ready to
install.
If the condensate cannot be discharged from the dehumidifier
(e.g. due to a clogged line), the condensate pump will switch off
the connected dehumidifier automatically. Once the fault has
been cleared, the dehumidifier will be switched back on (see also
Errors and faults).
The pump is suitable for a pump height of up to 4.3metres.
The device can be mounted to the wall or positioned on the floor
for operation.
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec DH-Serie wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info