local air conditioner PAC 3500
Ventilation
Info
Remove the exhaust air hose during ventilation.
In ventilation mode the room air is circulated, but not cooled.
1. Press the Mode button(14) until the ventilation LED(15) is
illuminated.
ð Ventilation mode is selected.
ð The current room temperature is indicated on the
segment display(20).
2. Press the Fan Speed button(19) to set the desired fan
stage.
ð The fan speed LED(16) indicates the selected fan stage.
ð The ventilation LED(15) will be illuminated to indicate
ventilation mode.
Changing the unit °C / °F
The temperature in the segment display(20) can be indicated in
°C or °F.
Please proceed as follows to change the temperature unit:
1. Simultaneously press and hold the Increase value(17) and
Decrease value(18) buttons for approx. 3s.
ð The displayed temperature is converted to the other
unit.
Setting the timer
The timer has two modes of operation:
automatic switch-on upon expiry of a preset number of
hours.
automatic switch-off upon expiry of a preset number of
hours.
This setting can be made at the device or using the remote
control.
The function can be set in all operating modes and also during
stand-by.
The number of hours can be set in hourly increments (1h to
24h).
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-on
ü The device is switched off.
1. Press the Timer button(21) until the timer LED(13) is
illuminated.
2. Set the desired number of hours by use of the Decrease
value(17) and Increase value(18) buttons.
ð The number of hours will be indicated on the segment
display(20).
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself on.
Notes regarding automatic switch-on:
If the device is disconnected from the power supply, all
settings for automatic switch-on are deleted.
Manually switching the device on disables the automatic
switch-on function.
If you select 0hours, the timer will be off.
Automatic switch-off
ü The device is switched on.
1. Press the Timer button(21) until the timer LED(13) is
illuminated.
2. Set the desired number of hours by use of the Decrease
value(17) and Increase value(18) buttons.
ð The number of hours will be indicated on the segment
display(20).
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself off.
Notes regarding automatic switch-off:
Pressing the power button(11) deactivates the automatic
switch-off function.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Empty the condensation tray if necessary.
If necessary, remove the condensation drain hose and any
residual fluid from it.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Observe the operating temperature according to the
Technical data chapter.
The condensation tray may be full. Empty the condensation
tray if necessary. The water filling level LED(12) must not
be illuminated.
Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec PAC3500 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec PAC3500

Trotec PAC3500 Bedienungsanleitung - Deutsch - 22 seiten

Trotec PAC3500 Bedienungsanleitung - Holländisch - 23 seiten

Trotec PAC3500 Bedienungsanleitung - Französisch - 23 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info