EN 10
local air conditioner PAC 3500 E
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery.
Insert suitable batteries in the remote control (seechapter
Technical annex).
Cool Fan Dry
Heat
Timer
°C
°F
Hr
Auto
Swing
TIMER SWING °C °F
UP
FAN
POWER
MODE
DOWN
17
33
27
26
32
37
36
18
25
29
34
19
35
23
31
No. Designation Meaning
17 TIMER button Switching the timer function on or off,
1 to 24hours in increments of 1h
18 FAN button Setting the fan speed in 3 stages:
high, medium and low
19 Increase value
button UP
Setting the target temperature for
cooling:
value range from 16°C to 30°C
Setting the number of hours for the
timer:
1 to 24hours in increments of 1h
23 Decrease value
button DOWN
25 POWER button Power button:
Switching the device on or off
26 MODE button Selection button for the mode of
operation
27 Fan speed
indication
Low =
Medium =
High =
29 Segment display Display of current room temperature
when in operation
Display of target temperature while
setting it
Display of timer
Display of error codes
31 TIMER indication Timer active
32 Battery indication Charging status of the batteries for
the remote control
33 Operating mode
indication
Cool = cooling
Fan = ventilation
Dry = dehumidification
No. Designation Meaning
34 °C/°F button Switching temperature indication
between °C and °F
35 SWING button Adjusting the position of the
ventilation flaps
36 Transmitter
indication
Indicates transmission to the device
when the button is pressed
37 Remote control
transmitter/
receiver
Communication between device and
remote control
Note:
After a longer period of non-use, the remote control will switch
to standby mode. Standby mode can be terminated by pressing
the POWER button on the remote control Please note that the
device automatically takes over the current settings from the
remote control.
Changing the unit °C / °F
The temperature in the segment display(29) can be indicated in
°C or °F.
Please proceed as follows to change the temperature unit:
1. Simultaneously press the UP(19) and DOWN(23) buttons.
Alternatively, you can press the °C / °F button(34) on the
remote control.
ð The displayed temperature is converted to the other unit.
Swing function
The swing function can be activated via the remote control or
directly at the device.
Using the swing function, you can adjust the position of the
ventilation flaps or activate continuous movement of the
ventilation flaps.
1. Simultaneously press the TIMER(17) and FAN(18) buttons
or press the SWING button(35) on the remote control.
ð The ventilation flaps move up and down continuously.
2. Press the TIMER(17) and FAN(18) buttons simultaneously
once again or press the SWING button(35) on the remote
control to stop the ventilation flaps in a certain position or
to switch the swing function off.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator.
The device will then carry out an automatic defrost. The
automatic defrost indication(30) appears on the display and
disappears again when automatic defrosting is finished.
The compressor switches off and the fan keeps running until
defrosting is completed. The duration of the defrost process can
vary.
Do not switch off the device during automatic defrost. Do not
remove the mains plug from the mains socket.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec PAC3500E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec PAC3500E

Trotec PAC3500E Bedienungsanleitung - Deutsch - 20 seiten

Trotec PAC3500E Bedienungsanleitung - Holländisch - 20 seiten

Trotec PAC3500E Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info