local air conditioner PAC 3900 X
Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
The electrical connection must correspond to the
specifications in chapter Technical data.
Insert the mains plug into a properly secured mains
socket.
Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.
Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
Make sure that the air inlet and outlet are not obstructed.
Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
Make sure that the suction side is kept free of dirt and
loose objects.
Only transport the device in an upright position with an
emptied condensation tray or drain hose.
Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Safety warnings for air conditioners filled with R290
Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
Only position the device in rooms where there is no
permanent source of ignition (e.g. open flames, an active
gas appliance or an electric heater).
Please note that the refrigerant is odourless.
Only install the device in compliance with the national
installation regulations.
Observe the national gas regulations.
Only install, operate and store the device PAC 3900 X in a
room measuring more than 13m
2
.
Store the device in a way that no mechanical damage can
occur.
Please note that the connected ducts must not contain any
sources of ignition.
R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.
Do not drill through or burn.
Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
Unventilated rooms, in which the device is installed,
operated or stored, must be built in a way to ensure that
potentially leaking refrigerant cannot accumulate. This
serves to avoid fire or explosion hazards resulting from an
ignition of the refrigerant by an electric furnace, cooking
stove or another ignition source.
The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Intended use
Only use the device for cooling, ventilating and dehumidifying
indoor air whilst adhering to the technical data.
Improper use
Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, such as alterations or
structural changes to the device, are forbidden.
Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec PAC3900X wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec PAC3900X

Trotec PAC3900X Bedienungsanleitung - Deutsch - 22 seiten

Trotec PAC3900X Bedienungsanleitung - Holländisch - 23 seiten

Trotec PAC3900X Bedienungsanleitung - Französisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info