756430
11
Zoom out
Zoom in
Vorherige Seite
1/19
Nächste Seite
EN 11
garden pump TGP 1025 E / TGP 1025 ES / TGP 1025 ES ES
Errors and faults
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Warning
The device is pressurized. Before opening the screw
plug at the water filler neck(3) or water drain
nozzle(5), the pressure must be released from the
pressure line via the lowest-level consumer.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check the current pressure on the pressure gauge(9). Only
when the pressure is below the switch-on pressure of
1.5bar will the device switch on and operate until reaching
the switch-off pressure of 3bar.
The device might have overheated and the thermal
protection circuit is activated.
If so, wait for approx. 10minutes before restarting the
device. If the device is not starting, have the electrics
checked by a specialist company or by Trotec.
The water temperature is above 35°C and the thermal
protection circuit is activated.
The device is running, but not sucking in any water:
Check whether the suction line is submerged in the
pumping medium and/or check whether the water level of
the pumping medium is sufficient.
Check whether the screw plugs at the water filler neck(3)
and water drain nozzle(5) are completely closed and
whether the seal is installed correctly.
Check the inside of the device for any remaining air. Open
the screw plug at the water filler neck(3) and fill the
device with water all the way to the edge.
Check the suction line and the connection for tightness.
Check whether the suction height is too high, and reduce it
if necessary.
Check whether the hose line is kinked or blocked. Remove
kinks and/ or blockages.
Insufficient or decreasing conveying capacity:
Check whether the suction height or pump height exceeds
the max. specifications indicated in the technical data, and
reduce it if necessary.
Check whether the hose line is kinked or blocked. Remove
kinks and/ or blockages.
Check whether the suction line is clogged at the intake
opening. Remove any dirt.
Inspect both the pressure and suction line for leaks, and
replace them if necessary.
The pump switches on and off too often:
Check whether the precharge pressure in the pressure
tank is set correctly; it should be 1.5 to 1.8bar. Please
refer to the chapter Checking the precharge pressure in
the pressure tank.
If the pressure tank cannot maintain the set precharge
pressure, the membrane inside the pressure tank is
damaged and must be replaced. If so, contact a specialist
company or Trotec.
Check whether the check valve at the suction line is
blocked or damaged. Remove the obstruction or replace
the check valve.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Notes on maintenance
Inside the device, there are no parts that need to be maintained
or lubricated by the user.
Note
If there is a danger of frost, drain all water from the
device via the water drain nozzle(5) to prevent the
device from being damaged. Before restart, the device
must be filled with water again.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec TGP1025ES wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec TGP1025ES

Trotec TGP1025ES Bedienungsanleitung - Deutsch - 20 seiten

Trotec TGP1025ES Bedienungsanleitung - Holländisch - 20 seiten

Trotec TGP1025ES Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info