User instructions – Adsorption dehumidifier TTR 400/400D/500D
Functional principle
TTR 400D/500D
Adsorption dehumidifiers work with a drying wheel (rotor) consisting of
layers of flat and corrugated fibres with a chemically bound silica gel.
This generates a honeycomb structure with numerous axial air channels
with a large surface and direct connections to the inner pore structure of
the silica gel.
Due to the favourable mechanic and physical properties of the drying wheel,
no silica gel is released and can be subject to saturated air (100 % rh),
however, not to drips of water. It is not flammable.
The basic design of a dehumidification unit is as follows:
• Fan(s) for air delivery
• At least two different sections for delivery of process air (to be dehu-
midified) and regeneration air (humid exhaust).
• Drying wheel for dehumidification
• Drive unit with gear motor, toothed belt disc and toothed belt
• Heating unit for heating of the regeneration air
During dehumidification, the drying wheel continuously turns at low
speed (3 to 30 rpm, depending on the configuration). This way, process
air and regeneration air are simultaneously applied to the drying wheel
via the sections so that it can permanently absorb and release humidity.
Process air
Air to be dehumidified is taken in by means of a fan. The process air (4)
flows through the dehumidification section (1) of the drying wheel. In this
process, the humidity in the air is removed by means of the absorbent
(silica gel) and bound (adsorption). Due to physical processes, the tem-
perature of the drying air is increased. In the further process, the dried air
(6) is delivered to the drying air outlet.
Regeneration air
Regeneration air is also taken in by means of a fan and passes through
the rinsing sector (3). During humidification, the drying wheel is heated
by the released heat of adsorption and regeneration. The rinsing sec-
tor is used for heat recovery and to cool the drying wheel which results
in reduced energy input and improved dehumidification performance, in
particular for lower dew points.
When flowing through the heating unit (7), the temperature of the air is
increased to approx. 100 - 120 °C (depending on the intake temperature),
while its relative humidity is considerably reduced.
Afterwards, the air that was prepared in this process absorbs the humid-
ity bound in the silica gel (desorption) when passing the regeneration
section (2). Afterwards, the extremely humid regeneration air (8) is deliv-
ered outside through the humid air outlet.
Fig.: Functional principle TTR 400D/500D
TTR 400
Process air
Air to be dehumidified is taken in by means of a fan and divided into two
air streams: Process air (4) and regeneration air (5).
The process air (4) flows through the dehumidification section (1) of the
drying wheel. In this process, the humidity in the air is removed by means
of the absorbent (silica gel) and bound (adsorption).
After having passed the section, dry air (6) is released into the space.
Regeneration air
The second air stream (5) is passed through the rinsing section as regen-
eration air. This section is used for the recovery of the heat of adsorption
generated during dehumidification.
At the same time, the drying wheel is cooled which results in reduced
energy input and improved dehumidification performance, in particular
for lower dew points.
Further on, the air stream is passed through a heating unit (7), the tem-
perature of the air is increased to approx. 100 - 120 °C (depending on the
intake temperature), while its relative humidity is considerably reduced.
Afterwards, the air that was prepared in this process absorbs the humid-
ity bound in the silica gel (desorption) when passing the regeneration
section (2). Afterwards, the extremely humid regeneration air (8) is deliv-
ered outside through the humid air outlet.
Fig.: Functional principle TTR 400
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec TTR 400 D wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec TTR 400 D

Trotec TTR 400 D Bedienungsanleitung - Deutsch - 20 seiten

Trotec TTR 400 D Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info