756418
12
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
12 EN
submerged clear water pump, near-ground suction TWP 4006 E / TWP 7506 E
Errors and faults
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Switch the device off.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the on-site fusing.
Check the power cable and mains plug for damages. If you
notice damages, do not try to take the device back into
operation. To avoid safety hazards, do not perform any
repairs. Dispose of the device as described in the Disposal
chapter.
Check whether the float switch is located above the
automatic switch-on position.
The device might have overheated and the thermal
protection circuit is activated.
If so, wait for approx. 10minutes before restarting the
device. If the device is not starting, have the electrics
checked by a specialist company or by Trotec.
The water temperature is above 35°C and the thermal
protection circuit is activated.
Check whether there are any foreign objects in the air
intake opening(6), the reducer(7) and/ or the hose or
pipe.
The device is running, but not pumping any water:
Check the inside of the device for any remaining air. Lower
the device into the water at a slight angle and wait for the
air to escape completely.
Switch the device off and on again several times while it is
in the water in order to support automatic ventilation.
Check whether the minimum water level has been
reached, see technical data. In order to start pumping, the
device requires a minimum water level.
Check whether the hoses are blocked and whether the
water contains any suspended matter with a particle size
of more than 5mm, which could clog up the device.
Check whether the used hose diameter is too small.
Check whether the hose line is kinked or blocked. Remove
kinks and/ or blockages.
Check whether the reducer(7), the backflow preventer(8)
and/ or the elbow(10) are clogged.
The device is not switching off automatically:
The float switch is hindered from lowering. Check whether
the float switch can move freely. Remove any blockages or
ensure sufficient freedom of movement for the float
switch.
The device switches off after a brief runtime:
Check whether the water temperature is too high. The
device might have overheated due to a too high water
temperature and the thermal protection circuit is activated.
Check the power connection.
Check the power cable and mains plug for damage.
Check the on-site fusing.
Check whether the hoses are blocked and whether the
water contains any suspended matter with a particle size
of more than 5mm, which could clog up the device. The
device might have overheated due to the blockage and the
thermal protection circuit is activated.
Insufficient or decreasing conveying capacity:
Check whether the hoses are blocked and whether the
water contains any suspended matter with a particle size
of more than 5mm, which could clog up the device.
Check the hose diameter and the delivery head. An
excessive delivery head paired with a small hose diameter
can cause a reduction of the conveying capacity.
Check whether the hose line is kinked or blocked. Remove
kinks and/ or blockages.
The connection system cannot be opened or closed:
Check the connection system for dirt and remove any dirt if
required, as described in the Cleaning chapter.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec TWP7506E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec TWP7506E

Trotec TWP7506E Bedienungsanleitung - Deutsch - 16 seiten

Trotec TWP7506E Bedienungsanleitung - Holländisch - 16 seiten

Trotec TWP7506E Bedienungsanleitung - Französisch - 16 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info